10 published item(s)

preprint2026arXiv

Characterization of the H2M Monolithic CMOS Sensor

The H2M (Hybrid-to-Monolithic) is a monolithic pixel sensor manufactured in a modified \SI{65}{\nano\meter}~CMOS imaging process with a small collection electrode. Its design addresses the challenges of porting an existing hybrid pixel detector architecture into a monolithic chip, using a digital-on-top design methodology, and developing a compact digital cell library. Each square pixel integrates an analog front-end and digital pulse processing with an 8-bit counter within a \SI{35}{\micro\meter}~pitch. This contribution presents the performance of H2M based on laboratory and test beam measurements, including a comparison with analog front-end simulations in terms of gain and noise. A particular emphasis is placed on backside thinning in order to reduce material budget, down to a total chip thickness of \SI{21}{\micro\meter} for which no degradation in MIP detection performance is observed. For all investigated samples, a MIP detection efficiency above \SI{99}{\%} is achieved below a threshold of approximately 205 electrons. At this threshold, the fake-hit rate corresponds to a matrix occupancy of fewer than one pixel per the \SI{500}{\nano\second}~frame. Measurements reveal a non-uniform in-pixel response, attributed to the formation of local potential wells in regions with low electric field. A simulation flow combining technology computer-aided design, Monte Carlo, and circuit simulations is used to investigate and describe this behavior, and is applied to develop mitigation strategies for future chip submissions with similar features.

preprint2022arXiv

Transient Monte Carlo Simulations for the Optimisation and Characterisation of Monolithic Silicon Sensors

An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach provides simultaneous access to precise sensor modelling and high statistics. The high simulation statistics enable the inclusion of Landau fluctuations and production of secondary particles, which offers a realistic simulation scenario. The transient simulation approach is an important tool to achieve an accurate time-resolved description of the sensor, which is crucial in the face of novel detector prototypes with increasingly precise timing capabilities. The simulated time resolution as a function of operating parameters as well as the full transient pulse can be monitored and assessed, which offers a new perspective on the optimisation and characterisation of silicon sensors. In this paper, a combination of electrostatic finite-element simulations using 3D TCAD and transient Monte Carlo simulations with the Allpix Squared framework are presented for a monolithic CMOS pixel sensor with a small collection diode, that is characterised by a highly inhomogeneous, complex electric field. The results are compared to transient 3D TCAD simulations that offer a precise simulation of the transient behaviour but long computation times. Additionally, the simulations are benchmarked against test-beam data and good agreement is found for the performance parameters over a wide range of different operation conditions.

preprint2021arXiv

ARRAY: An Open Source, Modular and Probe-Card based System with Integrated Switching Matrix for Characterisation of Large Area Silicon Pad Sensors

Silicon pad sensors are proposed as active material in highly granular sampling calorimeters of future collider experiments such as the Compact Linear Collider (CLIC) or the International Linear Collider (ILC). The electromagnetic section of these designs often include O(1000 m$^2$) of silicon pad sensors. For the luminosity measurement, a dedicated forward calorimeter called LumiCal is foreseen. More recently, the CMS experiment has decided to adopt the same concept in its endcap calorimeter upgrade for the HL-LHC. The sensors are typically produced from 6- or 8-inch wafers and consist of a few hundred smaller cells, each with an area of O(0.1 to 1 $\text{cm}^2$). For the prototyping phase of these projects, several design choices have to be evaluated while for mass production, thousands of sensors have to be tested for quality control. For the electrical characterisation of these sensors, it is important to bias them under realistic conditions. To fulfil these requirements, ARRAY, a compact, modular and cost efficient system for large area silicon pad sensor characterisation has been developed and successfully commissioned. It consists of two plugin printed circuit boards: an active switching matrix with 512 input channels that holds all controls and a passive probe card that connects to the sensor. The latter can then be adapted to any sensor geometry. All design files are open source. The system has been used to measure currents ranging from 500 pA to 5 $μ$A and capacitances between 5 pF and 100 pF. A precision of better than 0.2 pF on capacitance measurements in that range can be achieved. Examples of calibration and measurement results for leakage current and capacitance are presented.

preprint2021arXiv

Corryvreckan: A Modular 4D Track Reconstruction and Analysis Software for Test Beam Data

Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from multiple devices based on timestamps. Hit timing information, available with high precision from an increasing number of detectors, can be used in clustering and tracking to reduce combinatorics. Several algorithms, including an implementation of Millepede-II, are provided for offline alignment. A graphical user interface enables direct monitoring of the reconstruction progress and can be employed for quasi-online monitoring during data taking. This work introduces the Corryvreckan framework architecture and user interface, and provides a detailed overview of the event building algorithm. The reconstruction and analysis capabilities are demonstrated with data recorded at the DESY II Test Beam Facility using the EUDAQ2 data acquisition framework with an EUDET-type beam telescope, a Timepix3 timing reference, a fine-pitch planar silicon sensor with CLICpix2 readout and the AIDA Trigger Logic Unit. The individual steps of the reconstruction chain are presented in detail.

preprint2020arXiv

Combining TCAD and Monte Carlo Methods to Simulate CMOS Pixel Sensors with a Small Collection Electrode using the Allpix Squared Framework

Combining electrostatic field simulations with Monte Carlo methods enables realistic modeling of the detector response for novel monolithic silicon detectors with strongly non-linear electric fields. Both the precise field description and the inclusion of Landau fluctuations and production of secondary particles in the sensor are crucial ingredients for the understanding and reproduction of detector characteristics. In this paper, a CMOS pixel sensor with small collection electrode design, implemented in a high-resistivity epitaxial layer, is simulated by integrating a detailed electric field model from finite element TCAD into a Monte Carlo based simulation with the Allpix$^2$ framework. The simulation results are compared to data recorded in test-beam measurements and very good agreement is found for various quantities such as cluster size, spatial resolution and efficiency. Furthermore, the observables are studied as a function of the intra-pixel incidence position to enable a detailed comparison with the detector behavior observed in data. The validation of such simulations is fundamental for modeling the detector response and for predicting the performance of future prototype designs. Moreover, visualization plots extracted from the charge carrier drift model of the framework can aid in understanding the charge propagation behavior in different regions of the sensor.

preprint2013arXiv

Forward tracking at the next \boldmath{$e^+e^-$} collider Part II: experimental challenges and detector design

We present the second in a series of studies into the forward tracking system for a future linear $ e^+ e^- $ collider with a center-of-mass energy in the range from 250 GeV to 3 TeV. In this note a number of specific challenges are investigated, that have caused a degradation of the tracking and vertexing performance in the forward region in previous experiments. We perform a quantitative analysis of the dependence of the tracking performance on detector design parameters and identify several ways to mitigate the performance loss for charged particles emitted at shallow angle.

preprint2013arXiv

Physics at the CLIC e+e- Linear Collider -- Input to the Snowmass process 2013

This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accompanied by a paper describing the CLIC accelerator study, submitted to the Frontier Capabilities group of the Snowmass process.

preprint2013arXiv

Vertex-Detector R&D for CLIC

A detector concept based on hybrid planar pixel-detector technology is under development for the CLIC vertex detector. It comprises fast, low-power and small-pitch readout ASICs implemented in 65 nm CMOS technology (CLICpix) coupled to ultra-thin sensors via low-mass interconnects. The power dissipation of the readout chips is reduced by means of power pulsing, allowing for a cooling system based on forced gas flow. In this paper the CLIC vertex-detector requirements are reviewed and the current status of R&D on sensors, readout and detector integration is presented.

preprint2012arXiv

CLIC e+e- Linear Collider Studies

This document provides input from the CLIC e+e- linear collider studies to the update process of the European Strategy for Particle Physics. It is submitted on behalf of the CLIC/CTF3 collaboration and the CLIC physics and detector study. It describes the exploration of fundamental questions in particle physics at the energy frontier with a future TeV-scale e+e- linear collider based on the Compact Linear Collider (CLIC) two-beam acceleration technique. A high-luminosity high-energy e+e- collider allows for the exploration of Standard Model physics, such as precise measurements of the Higgs, top and gauge sectors, as well as for a multitude of searches for New Physics, either through direct discovery or indirectly, via high-precision observables. Given the current state of knowledge, following the observation of a \sim125 GeV Higgs-like particle at the LHC, and pending further LHC results at 8 TeV and 14 TeV, a linear e+e- collider built and operated in centre-of-mass energy stages from a few-hundred GeV up to a few TeV will be an ideal physics exploration tool, complementing the LHC. Two example scenarios are presented for a CLIC accelerator built in three main stages of 500 GeV, 1.4 (1.5) TeV, and 3 TeV, together with the layout and performance of the experiments and accompanied by cost estimates. The resulting CLIC physics potential and measurement precisions are illustrated through detector simulations under realistic beam conditions.