Researcher profile

Devon R. Mortensen

Devon R. Mortensen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

A Modern Laboratory XAFS Cookbook

We have recently demonstrated a very favorable, inexpensive modernization of lab-based x-ray absorption fine structure (XAFS) and high-resolution x-ray emission spectroscopy (XES) using only commercially-available optics and x-ray tube sources. Here, we survey several proven instrument designs that can be readily implemented in any laboratory setting to achieve synchrotron-quality XAFS and XES for many systems in the 5 keV to 10 keV energy range. These approaches are based on our immediate experience with the development of: (1) an inexpensive, low-powered monochromator capable of performing either XAFS or XES, (2) a mid-scale XAFS user facility having 10^6/sec flux with sub-eV bandwidth on each of two independent beamlines, and (3) multiple XES spectrometers having 3rd-generation synchrotron performance for battery and actinide research.

preprint2015arXiv

Benchtop Nonresonant X-ray Emission Spectroscopy: Coming Soon to Laboratories and XAS Beamlines Near You?

Recently developed instrumentation at the University of Washington has allowed for nonresonant x-ray emission spectra (XES) to be measured in a laboratory-setting with an inexpensive, easily operated system. We present a critical evaluation of this equipment by means of K\b{eta} and valence-level XES measurements for several Co compounds. We find peak count rates of ~5000/s for concentrated samples and a robust relative energy scale with reproducibility of 25 meV or better. We furthermore find excellent agreement with synchrotron measurements with only modest loss in energy resolution. Instruments such as ours, based on only conventional sources that are widely sold for elemental analysis by x-ray fluorescence, can fill an important role to diversify the research applications of XES both by their presence in non-synchrotron laboratories and by their use in conjunction with XAFS beamlines where the complementarity of XAFS and XES holds high scientific potential.