Researcher profile

Davide Fabris

Davide Fabris contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Single-shot implementation of dispersion-scan for the characterization of ultrashort laser pulses

We demonstrate a novel, single-shot ultrafast diagnostic, based on the dispersion-scan (d-scan) technique. In this implementation, rather than scanning wedges to vary the dispersion as in standard d-scan, the pulse to be measured experiences a spatially varying amount of dispersion in a Littrow prism. The resulting beam is then imaged into a second-harmonic generation crystal and an imaging spectrometer is used to measure the two-dimensional trace, which is analyzed using the d-scan retrieval algorithm. We compare the single-shot implementation with the standard d-scan for the measurement of sub-3.5-fs pulses from a hollow core fiber pulse compressor. We show that the retrieval algorithm used to extract amplitude and phase of the pulse provides comparable results, proving the validity of the new single-shot implementation down to near single-cycle durations.

preprint2013arXiv

Carrier-envelope phase stability of hollow-fibers used for high-energy, few-cycle pulse generation

We investigated the carrier-envelope phase (CEP) stability of a hollow-fiber setup used for high-energy, few-cycle pulse generation. Saturation of the output pulse energy is observed at 0.6 mJ for a 260 um inner-diameter, 1 m long fiber, statically filled with neon, with the pressure adjusted to achieve an output spectrum capable of supporting sub-4fs pulses. The maximum output pulse energy can be increased to 0.8mJ by using either differential pumping, or circularly polarized input pulses. We observe the onset of an ionization-induced CEP instability, which does not increase beyond an input pulse energy of 1.25 mJ due to losses in the fiber caused by ionization. There is no significant difference in the CEP stability with differential pumping compared to static-fill, demonstrating that gas flow in differentially pumped fibers does not degrade the CEP stabilization.