Source author record

David Weinberger

David Weinberger appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2022arXiv

Study of a possible silicon photomultiplier based readout of the large plastic scintillator neutron detector NeuLAND

The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its final configuration, NeuLAND will consist of 3000 2.7 m $\times$ 5 cm $\times$ 5 cm big plastic scintillator bars that are read out on each end by fast timing photomultipliers. Here, data from a comprehensive study of an alternative light readout scheme using silicon photomultipliers (SiPM) are reported. For this purpose, a NeuLAND bar was instrumented on each end with a SiPM-based prototype of the same geometry as a 1'' photomultiplier tube, including four 6 $\times$ 6 mm$^2$ SiPMs, amplifiers, high voltage supply, and microcontroller. Tests were carried out using the 35 MeV electron beam from the superconducting Electron Linac for beams with high Brilliance and low Emittance (ELBE) with its picosecond-level time jitter in two different modes of operation, namely parasitic mode with one electron per bunch and single-user mode with 1-60 electrons per bunch. Acqiris fast digitisers were used for data acquisition. In addition, off-beam tests using cosmic rays and the NeuLAND data acquisition scheme have been carried out. Typical time resolutions of $σ_t\leq$ 120 ps were found for $\geq$95% efficiency for minimum ionising particles, improving on previous work at ELBE and exceeding the NeuLAND timing goal of $σ_t$ < 150 ps. Over a range of 10-300 MeV deposited energy in the NeuLAND bar, the gain was found to deviate by $\leq$10% ($\leq$20%) from linearity for 35 mm (75 mm) SiPM pitch, respectively, satisfactory for calorimetric use of the full NeuLAND detector. The dark rate of the prototype studied was found to be lower than the expected cosmic-ray induced background in NeuLAND.