Researcher profile

David R. Scherer

David R. Scherer contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

A Review of Contemporary Atomic Frequency Standards

Atomic frequency standards are used to generate accurate and precise time and frequency, enabling many communications, synchronization, and navigation systems in modern life. GPS and other satellite navigation systems, voice and data telecommunications, and timestamping of financial transactions all rely on precise time and frequency enabled by atomic frequency standards. This review provides a snapshot and outlook of contemporary atomic frequency standards and the applications they enable. We provide a concise summary of the performance and physics of operation of current and future atomic frequency standards. Additionally, examples of emerging frequency standard technologies and prototype demonstrations are presented, with a focus on technologies expected to provide commercial or military utility within the next decade. We include a comparison of performance vs. size and power for current atomic frequency standards, and we compare early prototypes of next-generation frequency standards to current product trends. An empirical relationship between frequency standard performance and product size is developed and discussed. Finally, we provide a mapping between applications and frequency standard technologies.

preprint2018arXiv

Analysis of Short-Term Stability of Miniature 171Yb+ Buffer Gas Cooled Trapped Ion Clock

We demonstrate an improvement in short-term stability by a factor of 10 over a previous generation miniature buffer gas cooled trapped ion clock. We describe the enhancement to detection SNR that has enabled this improvement, the method of clock operation, and the measurement of clock short-term stability. Additionally, we numerically investigate the magnitude of the Dick effect in our pulsed ion clock.

preprint2014arXiv

Progress on a Miniature Cold-Atom Frequency Standard

Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.

preprint2012arXiv

Characterization of Alkali Metal Dispensers and Non-Evaporable Getter Pumps in Ultra-High Vacuum Systems for Cold Atomic Sensors

A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and non-evaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the non-evaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. We have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.