Source author record

David M. Webber

David M. Webber appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Manual Calibration System for Daya Bay Reactor Neutrino Experiment

The Daya Bay Reactor Neutrino Experiment has measured the last unknown neutrino mixing angle, θ13, to be non-zero at the 7.7σ level. This is the most precise measurement to θ13 to date. To further enhance the understanding of the response of the antineutrino detectors (ADs), a detailed calibration of an AD with the Manual Calibration System (MCS) was undertaken during the summer 2012 shutdown. The MCS is capable of placing a radioactive source with a positional accuracy of 25 mm in R direction, 20 mm in Z axis and 0.5° in Φ direction. A detailed description of the MCS is presented followed by a summary of its performance in the AD calibration run.

preprint2011arXiv

A new part-per-million measurement of the positive muon lifetime and determination of the Fermi Constant

The Fermi Constant, G_F, describes the strength of the weak force and is determined most precisely from the mean life of the positive muon, tau_mu. Advances in theory have reduced the theoretical uncertainty on G_F as calculated from tau_mu to a few tenths of a part per million (ppm). Until recently, the remaining uncertainty on G_F was entirely experimental and dominated by the uncertainty on tau_mu. We report the MuLan collaboration's recent 1.0 ppm measurement of the positive muon lifetime. This measurement is over a factor of 15 more precise than any previous measurement, and is the most precise particle lifetime ever measured. The experiment used a time-structured low-energy muon beam and an array of plastic scintillators read-out by waveform digitizers and a fast data acquisition system to record over 2 times 10^{12} muon decays. Two different in-vacuum muon-stopping targets were used in separate data-taking periods. The results from these two data-taking periods are in excellent agreement. The combined results give tau_{mu^+}({MuLan})=2196980.3(2.2) ps. This measurement of the muon lifetime gives the most precise value for the Fermi Constant: G_F({MuLan}) = 1.1663788 (7) \times 10^{-5} {GeV}^{-2} (0.6 ppm). The lifetime is also used to extract the mu^-p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g_P.

preprint2010arXiv

Toward a sub-ppm measurement of the Fermi constant

The Fermi constant, G_F, describes the strength of the weak force and is determined most precisely from the mean life of the positive muon, tau_mu. Advances in theory have reduced the theoretical uncertainty on G_F as calculated from tau_mu to a few tenths of a part per million (ppm). The remaining uncertainty on G_F is entirely experimental, and is dominated by the uncertainty on tau_mu. The MuLan experiment is designed to measure the muon lifetime to part-per-million precision, a better-than twenty-fold improvement over the previous generation of experiments. In 2007, we reported an intermediate result, tau_mu=2.197013(24) microseconds (11 ppm), which is in excellent agreement with the previous world average. This mean life was measured using a pulsed surface muon beam stopped in a ferromagnetic target, surrounded by a symmetric scintillator detector array. Since this intermediate measurement, the detector was instrumented with waveform digitizers, the muon beam rate and beam extinction were increased, and two data sets were acquired on different targets, each containing over 10^12 muon decays. These data will lead to a new determination of G_F to better than a part per million.