Source author record

Dario Motta

Dario Motta appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2007arXiv

A unified analysis of the reactor neutrino program towards the measurement of the theta_13 mixing angle

We present in this article a detailed quantitative discussion of the measurement of the leptonic mixing angle theta_13 through currently scheduled reactor neutrino oscillation experiments. We thus focus on Double Chooz (Phase I & II), Daya Bay (Phase I & II) and RENO experiments. We perform a unified analysis, including systematics, backgrounds and accurate experimental setup in each case. Each identified systematic error and background impact has been assessed on experimental setups following published data when available and extrapolating from Double Chooz acquired knowledge otherwise. After reviewing the experiments, we present a new analysis of their sensitivities to sin^2(2 theta_13) and study the impact of the different systematics based on the pulls approach. Through this generic statistical analysis we discuss the advantages and drawbacks of each experimental setup.

preprint2005arXiv

Prototype scintillator cell for an In-based solar neutrino detector

We describe the work carried out at MPIK to design, model, build and characterize a prototype cell filled with a novel indium-loaded scintillator of interest for real-time low energy solar neutrino spectroscopy. First, light propagation in optical modules was studied with experiments and Monte Carlo simulations. Subsequently a 5 cm x 5 cm x 100 cm prototype detector was set up and the optical performances of several samples were measured. We first tested a benchmark PXE-based scintillator, which performed an attenuation length of ~ 4.2 m and a photo-electron yield of ~ 730 pe/MeV. Then we measured three In-loaded samples. At an In-loading of 44 g/l, an energy resolution of ~ 11.6 % and a spatial resolution of ~ 7 cm were attained for 477 keV recoil electrons. The long-range attenuation length in the cell was ~1.3 m and the estimated photo-electron yield ~ 200 pe/MeV. Light attenuation and relative light output of all tested samples could be reproduced reasonably well by MC. All optical properties of this system have remained stable over a period of > 1 y.