Researcher profile

Danielle A. Braje

Danielle A. Braje contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2024arXiv

Emulated nuclear spin gyroscope with $^{15}$NV centers in diamond

Nuclear spins in solid-state platforms are promising for building rotation sensors due to their long coherence times. Among these platforms, nitrogen-vacancy centers have attracted considerable attention with ambient operating conditions. However, the current performance of NV gyroscopes remains limited by the degraded coherence when operating with large spin ensembles. Protecting the coherence of these systems requires a systematic study of the coherence decay mechanism. Here we present the use of nitrogen-15 nuclear spins of NV centers in building gyroscopes, benefiting from its simpler energy structure and vanishing nuclear quadrupole term compared with nitrogen-14 nuclear spins, though suffering from different challenges in coherence protection. We systematically reveal the coherence decay mechanism of the nuclear spin in different NV electronic spin manifolds and further develop a robust coherence protection protocol based on controlling the NV electronic spin only, achieving a 15-fold dephasing time improvement. With the developed coherence protection, we demonstrate an emulated gyroscope by measuring a designed rotation rate pattern, showing an order-of-magnitude sensitivity improvement.

preprint2022arXiv

A Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity

Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/$\sqrt{\textrm{Hz}}$. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.

preprint2020arXiv

A Polariton-Stabilized Spin Clock

Atom-like quantum systems in solids have been proposed as a compact alternative for atomic clocks, but realizing the potential of solid-state technology will requires an architecture design which overcomes traditional limitations such as magnetic and temperature-induced systematics. Here, we propose a solution to this problem: a `solid-state spin clock' that hybridizes a microwave resonator with a magnetic-field-insensitive spin transition within the ground state of the diamond nitrogen-vacancy center. Detailed numerical and analytical modeling of this `polariton-stabilized' spin clock (PSSC) indicates a potential fractional frequency instability below $10^{-13}$ at 1 second measurement time, assuming present-day experimental parameters. This stability would represent a significant improvement over the state-of-the-art in miniaturized atomic vapor clocks.

preprint2011arXiv

Sub-micrometer epitaxial Josephson junctions for quantum circuits

We present a fabrication scheme and testing results for epitaxial sub-micrometer Josephson junctions. The junctions are made using a high-temperature (1170 K) "via process" yielding junctions as small as 0.8 mu m in diameter by use of optical lithography. Sapphire (Al2O3) tunnel-barriers are grown on an epitaxial Re/Ti multilayer base-electrode. We have fabricated devices with both Re and Al top electrodes. While room-temperature (295 K) resistance versus area data are favorable for both types of top electrodes, the low-temperature (50 mK) data show that junctions with the Al top electrode have a much higher subgap resistance. The microwave loss properties of the junctions have been measured by use of superconducting Josephson junction qubits. The results show that high subgap resistance correlates to improved qubit performance.