Source author record

Daniel Rüschen

Daniel Rüschen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2022arXiv

Towards Real-Time Monitoring and Control of Water Networks

Water networks are used in numerous applications, all of which have the essential task of real-time monitoring and control of water states. A framework for the generation of efficient models of water networks suitable for real-time monitoring and control purposes is proposed. The proposed models preserve the distributed parameter character of the connected local elements. Hence, the spatial resolution of the property under consideration is recovered. The real-time feasibility of the network model is ensured by means of reduced order modeling of the models constituting components. A novel model order reduction procedure that preserves the model parametric dependency is introduced. The proposed concept is evaluated with the water temperature as the property under consideration. The formulated model is applied for the prediction of the water temperature within an experimental test bench of a 60 meter exemplary circulation network at the company VIEGA. A reduced order model (ROM) with a 50 mm spatial resolution, i.e. 1200 discretization points, is constructed and utilized as the identification model for a single path of the test bench. Afterwards, the ROM is evaluated in a Hardware in the Loop experiment for the prediction of the downstream temperature showing high prediction accuracy with mean relative error below 3.5 \%. The ROM single step computation time did not exceed 2 msec highlighting the real-time potential of the method. Moreover, full network model validation experiments featuring both diffusion and transport dominated parts were conducted. The network model is able to predict the temperature evolution, flow rate, and pressure accurately at the different paths of the network with mean relative errors below 4 \%, 2 \%, and 2 \%, respectively.