Source author record

Ahmed Elkhashap

Ahmed Elkhashap appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Model Order Reduction of The Time-Dependent Advection-Diffusion-Reaction Equation with Time-Varying Coefficients: Application to Real-Time Water Quality Monitoring

Advection-Diffusion-Reaction (ADR) Partial Differential Equations (PDEs) appear in a wide spectrum of applications such as chemical reactors, concentration flows, and biological systems. A large number of these applications require the solution of ADR equations involving time-varying coefficients, where analytical solutions are usually intractable. Numerical solutions on the other hand require fine discretization and are computationally very demanding. Consequently, the models are normally not suitable for real-time monitoring and control purposes. In this contribution, a reduced order modeling method for a general ADR system with time-varying coefficients is proposed. Optimality of the reduced order model regarding the reduction induced error is achieved by using an H2-norm reduction method. The efficacy of the method is demonstrated using two test cases. Namely, a case for an ADR with arbitrary dynamics varying coefficients and a second case including the modeling of an exemplary water quality distribution path with randomly generated demand. The reduced order models are evaluated against high fidelity simulations using MATLAB's finite element method PDE toolbox. It is shown that the reduction can achieve a significant computational speedup allowing for the usage of the model for real-time applications with sampling times in milliseconds range. Moreover, the constructed ROM is shown to achieve high prediction accuracy with the normalized mean square error below 2.3 % for a real-world water quality simulation test case.

preprint2022arXiv

Towards Real-Time Monitoring and Control of Water Networks

Water networks are used in numerous applications, all of which have the essential task of real-time monitoring and control of water states. A framework for the generation of efficient models of water networks suitable for real-time monitoring and control purposes is proposed. The proposed models preserve the distributed parameter character of the connected local elements. Hence, the spatial resolution of the property under consideration is recovered. The real-time feasibility of the network model is ensured by means of reduced order modeling of the models constituting components. A novel model order reduction procedure that preserves the model parametric dependency is introduced. The proposed concept is evaluated with the water temperature as the property under consideration. The formulated model is applied for the prediction of the water temperature within an experimental test bench of a 60 meter exemplary circulation network at the company VIEGA. A reduced order model (ROM) with a 50 mm spatial resolution, i.e. 1200 discretization points, is constructed and utilized as the identification model for a single path of the test bench. Afterwards, the ROM is evaluated in a Hardware in the Loop experiment for the prediction of the downstream temperature showing high prediction accuracy with mean relative error below 3.5 \%. The ROM single step computation time did not exceed 2 msec highlighting the real-time potential of the method. Moreover, full network model validation experiments featuring both diffusion and transport dominated parts were conducted. The network model is able to predict the temperature evolution, flow rate, and pressure accurately at the different paths of the network with mean relative errors below 4 \%, 2 \%, and 2 \%, respectively.