Source author record

Daniel Razansky

Daniel Razansky appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Dual-Mode Volumetric Optoacoustic and Contrast Enhanced Ultrasound Imaging with Spherical Matrix Arrays

Spherical matrix arrays arguably represent an advantageous tomographic detection geometry for non-invasive deep tissue mapping of vascular networks and oxygenation with volumetric optoacoustic tomography (VOT). Hybridization of VOT with ultrasound (US) imaging remains difficult with this configuration due to the relatively large inter-element pitch of spherical arrays. We suggest a new approach for combining VOT and US contrast-enhanced imaging employing injection of clinically-approved microbubbles. Power Doppler (PD) and US localization imaging were enabled with a sparse US acquisition sequence and model-based inversion based on infimal convolution of total variation (ICTV) regularization. Experiments in tissue-mimicking phantoms and in vivo in mice demonstrate the powerful capabilities of the new dual-mode imaging system for blood velocity mapping and anatomical imaging with enhanced resolution and contrast.

preprint2020arXiv

Noninvasive three-dimensional optoacoustic localization microangiography of deep tissues

Structural microvascular alterations and dysfunction serve as key disease indicators of cancer, diabetes, ischemic stroke, neurodegenerative disorders and many other conditions. In vivo visualization of the microvasculature has traditionally been restricted to millimeter scale depths accessible with optical microscopy. Optoacoustic imaging has enabled breaking through the barrier imposed by light diffusion to map functional hemodynamic parameters in deep-seated vessels, but diffraction and dispersion of ultrasound waves in heterogeneous living tissues prevents reaching capillary resolution. Herein, we demonstrate three-dimensional microangiography of deep mouse brain beyond the acoustic diffraction limit (<20$μ$m resolution) through the intact scalp and skull via optoacoustic localization of sparsely-distributed highly absorbing microparticles. This was enabled by devising 5$μ$m sized extremely absorbing dichloromethane microdroplets exhibiting four orders of magnitude higher optical absorption than red blood cells at near-infrared wavelengths, thus facilitating in vivo compatibility and single particle sensitivity in the presence of highly absorbing blood background. Accurate mapping of the blood flow velocity within microvascular structures was also facilitated by the high 3D frame rate of the optoacoustic tomography system. We further show that the detected optoacoustic signal intensities from the localized particles may serve for estimating the light fluence distribution within optically heterogeneous tissues, a long-standing quantification challenge in biomedical optics. Given the intrinsic sensitivity of optoacoustics to various functional, metabolic and molecular events in living tissues, this new approach paves the way for non-invasive deep-tissue microscopic observations with unrivaled resolution, contrast and speed.

preprint2015arXiv

Functional optoacoustic neuro-tomography (FONT) for whole-brain monitoring of calcium indicators

Non-invasive observation of spatiotemporal neural activity of large neural populations distributed over entire brains is a longstanding goal of neuroscience. We developed a real-time volumetric and multispectral optoacoustic tomography platform for imaging of neural activation deep in scattering brains. The system can record 100 volumetric frames per second across a 200mm3 field of view and spatial resolutions below 70um. Experiments performed in immobilized and freely swimming larvae and in adult zebrafish brains demonstrate, for the first time, the fundamental ability to optoacoustically track neural calcium dynamics in animals labeled with genetically encoded calcium indicator GCaMP5G, while overcoming the longstanding penetration barrier of optical imaging in scattering brains. The newly developed platform offers unprecedented capabilities for functional whole-brain observations of fast calcium dynamics; in combination with optoacoustics' well-established capacity in resolving vascular hemodynamics, it could open new vistas in the study of neural activity and neurovascular coupling in health and disease.

preprint2015arXiv

Simultaneous control of volumetric light distribution through turbid media using real-time three-dimensional optoacoustic feedback

Focusing light through turbid media presents a highly fascinating challenge in modern biophotonics. The unique capability of optoacoustics for high resolution imaging of light absorption contrast in deep tissues can provide a natural and efficient feedback to control light delivery in scattering medium. While basic feasibility of using optoacoustic readings as a feedback mechanism for wavefront shaping has been recently reported, the suggested approaches may require long acquisition times making them challenging to be translated into realistic tissue environments. In an attempt to significantly accelerate dynamic wavefront shaping capabilities, we present here a feedback-based approach using real-time three-dimensional optoacoustic imaging assisted with genetic-algorithm-based optimization. The new technique offers robust performance in the presence of noisy measurements and can simultaneously control the scattered wave field in an entire volumetric region.

preprint2014arXiv

High contrast imaging of reversibly switchable fluorescent proteins via temporally unmixed Multispectral Optoacoustic Tomography (tuMSOT)

Photocontrol of reversibly switchable fluorescent proteins (RSFPs) was used to program optoacoustic signal time courses that were temporally unmixed to increase the proteins contrast-to-noise-ratios (CNRs) in optoacoustic imaging. In this way, two variants of the RSFP Dronpa with very similar optoacoustic spectra could be readily discriminated in the presence of highly absorbing blood. Addition of temporal unmixing to multispectral optoacoustic tomography (tuMSOT) in conjunction with synthetic or genetically controlled photochromic contrast agents and customized photoswitching schedules can increase the performance of multiplexed and high contrast molecular optoacoustic imaging.