Source author record

Daniel P. Violette

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
2topics
4close collaborators

Published work

2 publications

preprint2022arXiv

Testing Station for Fast Screening of Through Silicon Via (TSV)-enabled Application Specific Integrated Circuits (ASICs) for Hard X-ray Imaging Detectors

Application Specific Integrated Circuits (ASICs) are used in space-borne instruments for signal processing and detector readout. The electrical interface of these ASICs to frontend printed circuit boards (PCBs) is commonly accomplished with wire bonds. Through Silicon Via (TSV) technology has been proposed as an alternative interconnect technique that will reduce assembly complexity of ASIC packaging by replacing wire bonding with flip-chip bonding. TSV technology is advantageous in large detector arrays where TSVs enable close detector tiling on all sides. Wafer-level probe card testing of TSV ASICs is frustrated by solder balls introduced onto the ASIC surface for flip-chip bonding that hamper alignment. Therefore, we developed the ASIC Test Stand (ATS) to enable rapid screening and characterization of individual ASIC die. We successfully demonstrated ATS operation on ASICs originally developed for CdZnTe detectors on the Nuclear Spectroscopic and Telescope Array (NuSTAR) mission that were later modified with TSVs in a via-last process. We tested both back-side blind-TSVs and front-side through-TSVs, with results from internal test pulser measurements that demonstrate performance equal to or exceeding the probe card wafer-level testing data. The ATS can easily be expanded or duplicated in order to parallelize ASIC screening for large area imaging detectors of future space programs.

preprint2020arXiv

HCF (HREXI Calibration Facility): Mapping out sub-pixel level responses from high resolution Cadmium Zinc Telluride (CZT) imaging X-ray detectors

The High Resolution Energetic X-Ray Imager (HREXI) CZT detector development program at Harvard is aimed at developing tiled arrays of finely pixelated CZT detectors for use in wide-field coded aperture 3-200 keV X-ray telescopes. A pixel size of ≃\simeq 600 μmμm has already been achieved in the ProtoEXIST2 (P2) detector plane with CZT read out by the NuSTAR ASIC. This paves the way for even smaller 300 μmμm pixels in the next generation HREXI detectors. This article describes a new HREXI calibration facility (HCF) which enables a high resolution sub-pixel level (100 μmμm) 2D scan of a 256 cm2cm^2 tiled array of 2 ×\times 2 cm CZT detectors illuminated by a bright X-ray AmpTek Mini-X tube source at timescales of around a day. HCF is a significant improvement from the previous apparatus used for scanning these detectors which took ≃\simeq 3 weeks to complete a 1D scan of a similar detector plane. Moreover, HCF has the capability to scan a large tiled array of CZT detectors (32cm×32cm32cm \times 32cm) at 100 μmμm resolution in the 10 - 50 keV energy range which was not possible previously. This paper describes the design, construction, and implementation of HCF for the calibration of the P2 detector plane.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.