Researcher profile

Damir Juric

Damir Juric contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

Interfacial standing wave-patterns disentangle dilatational and shear surface viscous effects

Dilatational and shear surface viscosities are highly correlated parameters, making their individual contributions difficult to disentangle in Stokes flow, linearised flow models, or two-dimensional flows. We therefore investigate the three-dimensional interfacial standing waves as a means to decouple the influence of dilatational and shear surface viscosities. Two dimensionless controlling parameters are introduced: $Bq$, the total Boussinesq number, which quantifies the the relative importance of surface viscous stresses compared with bulk viscous stresses, and $\tan χ$, which quantifies the ratio of surface dilatational viscosity to surface shear viscosity. The growth rates and threshold accelerations are independent of $χ$, consistent with previous theoretical predictions. Nonlinear analyses of square and hexagonal patterns reveal that Fourier decomposition of wave-patterns can effectively decouple the intricate dynamics into axial modes, where the waves are weakly dependent on $χ$, and oblique modes, where additional damping occurs in the shear surface viscous dominant interface. These results demonstrate that Faraday wave-patterns provide a route for identifying and quantifying the distinct roles of dilatational and shear surface viscosities.

preprint2022arXiv

Human Evaluation and Correlation with Automatic Metrics in Consultation Note Generation

In recent years, machine learning models have rapidly become better at generating clinical consultation notes; yet, there is little work on how to properly evaluate the generated consultation notes to understand the impact they may have on both the clinician using them and the patient's clinical safety. To address this we present an extensive human evaluation study of consultation notes where 5 clinicians (i) listen to 57 mock consultations, (ii) write their own notes, (iii) post-edit a number of automatically generated notes, and (iv) extract all the errors, both quantitative and qualitative. We then carry out a correlation study with 18 automatic quality metrics and the human judgements. We find that a simple, character-based Levenshtein distance metric performs on par if not better than common model-based metrics like BertScore. All our findings and annotations are open-sourced.

preprint2021arXiv

Towards more patient friendly clinical notes through language models and ontologies

Clinical notes are an efficient way to record patient information but are notoriously hard to decipher for non-experts. Automatically simplifying medical text can empower patients with valuable information about their health, while saving clinicians time. We present a novel approach to automated simplification of medical text based on word frequencies and language modelling, grounded on medical ontologies enriched with layman terms. We release a new dataset of pairs of publicly available medical sentences and a version of them simplified by clinicians. Also, we define a novel text simplification metric and evaluation framework, which we use to conduct a large-scale human evaluation of our method against the state of the art. Our method based on a language model trained on medical forum data generates simpler sentences while preserving both grammar and the original meaning, surpassing the current state of the art.

preprint2020arXiv

Can Embeddings Adequately Represent Medical Terminology? New Large-Scale Medical Term Similarity Datasets Have the Answer!

A large number of embeddings trained on medical data have emerged, but it remains unclear how well they represent medical terminology, in particular whether the close relationship of semantically similar medical terms is encoded in these embeddings. To date, only small datasets for testing medical term similarity are available, not allowing to draw conclusions about the generalisability of embeddings to the enormous amount of medical terms used by doctors. We present multiple automatically created large-scale medical term similarity datasets and confirm their high quality in an annotation study with doctors. We evaluate state-of-the-art word and contextual embeddings on our new datasets, comparing multiple vector similarity metrics and word vector aggregation techniques. Our results show that current embeddings are limited in their ability to adequately encode medical terms. The novel datasets thus form a challenging new benchmark for the development of medical embeddings able to accurately represent the whole medical terminology.

preprint2020arXiv

Effect of surfactant on elongated bubbles in capillary tubes at high Reynolds number

The effect of surfactants on the tail and film dynamics of elongated gas bubbles propagating through circular capillary tubes is investigated by means of an extensive three-dimensional numerical study using a hybrid front-tracking/level-set method. The focus is on the visco-inertial regime, which occurs when the Reynolds number of the flow is much larger than unity. Under these conditions, `clean' bubbles exhibit interface undulations in the proximity of the tail \cite{Magnini_prf_2017}, with an amplitude that increases with the Reynolds number. We perform a systematic analysis of the impact of a wide range of surfactant properties, including elasticity, bulk surfactant concentration, solubility, and diffusivity, on the bubble and flow dynamics in the presence of inertial effects. The results show that the introduction of surfactants is effective in suppressing the tail undulations as they tend to accumulate near the bubble tail. Here, large Marangoni stresses are generated, which lead to a local `rigidification' of the bubble. This effect becomes more pronounced for larger surfactant elasticities and adsorption depths. At reduced surfactant solubility, a thicker rigid film region forms at the bubble rear, where a Couette film flow is established, while undulations still appear at the trailing edge of the downstream `clean' film region. In such conditions, the bubble length becomes an influential parameter, with short bubbles becoming completely rigid.