Source author record

D. Venos

D. Venos appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN

We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass $m_{4}$. The analysis is sensitive to a fourth mass state $m^2_{4} \lesssim$ 1000 eV$^2$ and to active-to-sterile neutrino mixing down to $|U_{e4}|^2 \gtrsim 2\cdot10^{-2}$. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results and improve the Troitsk bound for $m^2_{4} <$ 30 eV$^2$. The reactor and gallium anomalies are constrained for $ 100 < Δ{m}^2_{41} < 1000$ eV$^2$.

preprint2016arXiv

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

preprint2011arXiv

Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project

The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been investigated. To do so, a cryogenic trap has been connected to the source for about 10 days, after which it was removed and probed for the strongest 83Rb gamma-rays with an ultra-sensitive Germanium detector. No signal has been found. The corresponding upper limit on the released 83Rb activity means that the investigated type of source can be used in the XENON project and similar low-background experiments as 83mKr generator without a significant risk of contaminating the detector. The measurements also allow to set upper limits on the possible release of the isotopes 84Rb and 86Rb, traces of which were created alongside the production of 83Rb at the Rez cyclotron.

preprint2010arXiv

Feasibility of photoelectron sources for testing the energy scale stablity of the KATRIN beta-ray spectrometer

Photoabsorption of nuclear gamma-rays in thin metallic convertors was examined with the aim to produce monoenergetic photoelectrons of kinetic energy around 18.6 keV and natural width of about 1 eV. Calculations were carried out for commercial photon sources of 241Am (1.1 GBq) and 119mSn (0.5 GBq) irradiating Co and Ti convertors. Photoelectrons ejected by 241Am gamma- and X-rays from Co convertors of various thickness were measured with two electrostatic spectrometers.

preprint2010arXiv

Magnetic moment of Ag-104(m) and the hyperfine magnetic field of Ag in Fe using nuclear magnetic resonance on oriented nuclei

Nuclear magnetic resonance (NMR/ON) measurements with beta- and gamma-ray detection have been performed on oriented Ag-104(g,m) nuclei with the NICOLE He-3-He-4 dilution refrigerator setup at ISOLDE/CERN. For Ag-104(g) (I-pi = 5(+)) the gamma-NMR/ON resonance signal was found at nu = 266.70(5) MHz. Combining this result with the known magnetic moment for this isotope, the magnetic hyperfine field of Ag impurities in an Fe host at low temperature (< 1 K) is found to be vertical bar B-hf(AgFe)vertical bar = 44.709(35) T. A detailed analysis of other relevant data available in the literature yields three more values for this hyperfine field. Averaging all four values yields a new and precise value for the hyperfine field of Ag in Fe; that is, vertical bar B-hf(AgFe)vertical bar = 44.692(30) T. For Ag-104(m) (I-pi = 2(+)), the anisotropy of the beta particles provided the NMR/ON resonance signal at nu = 627.7(4) MHz. Using the new value for the hyperfine field of Ag in Fe, this frequency corresponds to the magnetic moment mu(Ag-104m) = +3.691(3) mu(N), which is significantly more precise than previous results. The magnetic moments of the even-A Ag102 -110 isotopes are discussed in view of the competition between the (pi g(9/2))(7/2+)(-3)(nu d(5/2)nu g(7/2))(5/2+) and the (pi g(9/2))(9/2+)(-3)(nu d(5/2)nu g(7/2))(5/2+) configurations. The magnetic moments of the ground and isomeric states of Ag-104 can be explained by an almost complete mixing of these two configurations.

preprint2010arXiv

Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr

A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived 83m-Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67E-6 events/kg/day in the next generation of LXe dark matter direct detection searches