Source author record

D. V. Pelekhov

D. V. Pelekhov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2014arXiv

Observation of Pure Spin Transport in a Diamond Spin Wire

Spin transport electronics - spintronics - focuses on utilizing electron spin as a state variable for quantum and classical information processing and storage. Some insulating materials, such as diamond, offer defect centers whose associated spins are well-isolated from their environment giving them long coherence times; however, spin interactions are important for transport, entanglement, and read-out. Here, we report direct measurement of pure spin transport - free of any charge motion - within a nanoscale quasi 1D 'spin wire', and find a spin diffusion length ~ 700 nm. We exploit the statistical fluctuations of a small number of spins ($\sqrt{N}$ < 100 net spins) which are in thermal equilibrium and have no imposed polarization gradient. The spin transport proceeds by means of magnetic dipole interactions that induce flip-flop transitions, a mechanism that can enable highly efficient, even reversible, pure spin currents. To further study the dynamics within the spin wire, we implement a magnetic resonance protocol that improves spatial resolution and provides nanoscale spectroscopic information which confirms the observed spin transport. This spectroscopic tool opens a potential route for spatially encoding spin information in long-lived nuclear spin states. Our measurements probe intrinsic spin dynamics at the nanometre scale, providing detailed insight needed for practical devices which seek to control spin.

preprint2013arXiv

Spin accumulation detection of FMR driven spin pumping in silicon-based metal-oxide-semiconductor heterostructures

The use of the spin Hall effect and its inverse to electrically detect and manipulate dynamic spin currents generated via ferromagnetic resonance (FMR) driven spin pumping has enabled the investigation of these dynamically injected currents across a wide variety of ferromagnetic materials. However, while this approach has proven to be an invaluable diagnostic for exploring the spin pumping process it requires strong spin-orbit coupling, thus substantially limiting the materials basis available for the detector/channel material (primarily Pt, W and Ta). Here, we report FMR driven spin pumping into a weak spin-orbit channel through the measurement of a spin accumulation voltage in a Si-based metal-oxide-semiconductor (MOS) heterostructure. This alternate experimental approach enables the investigation of dynamic spin pumping in a broad class of materials with weak spin-orbit coupling and long spin lifetime while providing additional information regarding the phase evolution of the injected spin ensemble via Hanle-based measurements of the effective spin lifetime.

preprint2010arXiv

Quantitative magnetic force microscopy on permalloy dots using an iron filled carbon nanotube probe

We have characterized a new Magnetic Force Microscopy (MFM) probe based on an iron filled carbon nanotube (FeCNT) using MFM imaging on permalloy (Py) disks saturated in a high magnetic field perpendicular to the disk plane. The experimental data are accurately modeled by describing the FeCNT probe as having a single magnetic monopole at its tip whose effective magnetic charge is determined by the diameter of the iron wire enclosed in the carbon nanotube and its saturation magnetization 4 πM_s ~ 2.2 x 10^4 G. A magnetic monopole probe enables quantitative measurements of the magnetic field gradient close to the sample surface. The lateral resolution is defined by the diameter of the iron wire ~15 nm and the probe-sample separation. As a demonstration, the magnetic field gradients close to the surface of a Py dot in domain and vortex states were imaged.

preprint2008arXiv

Manipulating Spins by Cantilever Synchronized Frequency Modulation: A Variable Resolution Magnetic Resonance Force Microscope

We report a new spin manipulation protocol for periodically reversing the sample magnetization for Magnetic Resonance Force Microscopy. The protocol modulates the microwave excitation frequency synchronously with the position of the oscillating detection cantilever, thus allowing manipulation of the spin magnetization independent of both magnetic field gradient strength and cantilever response time. This allows continuous variation of the detected sample volume and is effective regardless of spin relaxation rate. This enhanced flexibility improves the utility of MRFM as a generally applicable imaging and characterization tool.