Source author record

D. Stach

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
3topics
4close collaborators

Published work

4 publications

preprint2019arXiv

A Timing RPC with low resistive ceramic electrodes

For precise start time determination a Beam Fragmentation T0_0 Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at Darmstadt/Germany. This detector will be located around the beam pipe, covering the front area of the Projectile Spectator Detector. The fluxes at this region are expected to exceed 105^5cm−2^{-2}s−1^{-1}. Resistive plate chambers (RPC) with ceramic composite electrodes could be use because of their high rate capabilities and radiation hardness of material. Efficiency ≥\ge 97\%, time resolution ≤\le 90 ps and rate capability ≥\ge 105^5cm−2^{-2}s−1^{-1} were confirmed during many tests with high beam fluxes of relativistic electrons. We confirm the stability of these characteristics with low resistive Si3_3N4_4/SiC floating electrodes for a prototype of eight small RPCs, where each of them contains six gas gaps. The active RPC size amounts 20×\times20 mm2^2 produced on basis of Al3_3O2_2 and Si3_3N4_4/SiC ceramics. Recent test results obtained with relativistic electrons at the linear accelerator ELBE of the Helmholtz-Zentrum Dresden-Rossendorf with new PADI-10 Front-end electronic will be presented.

preprint2016arXiv

Response of Multi-strip Multi-gap Resistive Plate Chamber

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm ×\times 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE at Helmholtz-Zentrum Dresden-Rossendorf. In this report the response of SINP developed MMRPC with different controlling parameters is described in details. The obtained time resolution (σtσ_t) of the detector after slew correction was 91.5± \pm 3 ps. Position resolution measured along (σxσ_x) and across (σyσ_y) the strip was 2.8±\pm0.6 cm and 0.58 cm, respectively. The measured absolute efficiency of the detector for minimum ionizing particle like electron was 95.8±\pm1.3 %\%. Better timing resolution of the detector can be achieved by restricting the events to a single strip. The response of the detector was mainly in avalanche mode but a few percentage of streamer mode response was also observed. A comparison of the response of these two modes with trigger rate was studied

preprint2014arXiv

Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons

Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment.

preprint2013arXiv

Nuclear astrophysics with radioactive ions at FAIR

The nucleosynthesis of elements beyond iron is dominated by neutron captures in the s and r processes. However, 32 stable, proton-rich isotopes cannot be formed during those processes, because they are shielded from the s-process flow and r-process beta-decay chains. These nuclei are attributed to the p and rp process. For all those processes, current research in nuclear astrophysics addresses the need for more precise reaction data involving radioactive isotopes. Depending on the particular reaction, direct or inverse kinematics, forward or time-reversed direction are investigated to determine or at least to constrain the desired reaction cross sections. The Facility for Antiproton and Ion Research (FAIR) will offer unique, unprecedented opportunities to investigate many of the important reactions. The high yield of radioactive isotopes, even far away from the valley of stability, allows the investigation of isotopes involved in processes as exotic as the r or rp processes.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.