Source author record

D. Michael

D. Michael appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

First measurement of electron neutrino appearance in NOvA

We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.

preprint2016arXiv

First measurement of muon-neutrino disappearance in NOvA

This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.

preprint2011arXiv

Comparisons of the MINOS Near and Far Detector Readout Systems at a Test Beam

MINOS is a long baseline neutrino oscillation experiment that uses two detectors separated by 734 km. The readout systems used for the two detectors are different and have to be independently calibrated. To verify and make a direct comparison of the calibrated response of the two readout systems, test beam data were acquired using a smaller calibration detector. This detector was simultaneously instrumented with both readout systems and exposed to the CERN PS T7 test beam. Differences in the calibrated response of the two systems are shown to arise from differences in response non-linearity, photomultiplier crosstalk, and threshold effects at the few percent level. These differences are reproduced by the Monte Carlo (MC) simulation to better than 1% and a scheme that corrects for these differences by calibrating the MC to match the data in each detector separately is presented. The overall difference in calorimetric response between the two readout systems is shown to be consistent with zero to a precision of 1.3% in data and 0.3% in MC with no significant energy dependence.