Source author record

D. Meer

D. Meer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2019arXiv

Large energy acceptance gantry for proton therapy utilizing superconducting technology

When using superconducting (SC) magnets in a gantry for proton therapy, the gantry will benefit from some reduction in size and a large reduction in weight. In this contribution we show an important additional advantage of SC magnets in proton therapy treatments. We present the design of a gantry with a SC bending section and achromatic beam optics with a very large beam momentum acceptance of $\pm15\%$. Due to the related very large energy acceptance, approximately 70% of the treatments can be performed without changing the magnetic field for synchronization with energy modulation. In our design this is combined with a 2D lateral scanning system and a fast degrader mounted in the gantry, so that this gantry will be able to perform pencil beam scanning with very rapid energy variations at the patient, allowing a significant reduction of the irradiation time. We describe the iterative process we have applied to design the magnets and the beam transport, for which we have used different codes. COSY Infinity and OPAL have been used to design the beam transport optics and to track the particles in the magnetic fields, which are produced by the magnets designed in Opera. With beam optics calculations we have derived an optimal achromatic beam transport with the large momentum acceptance of the proton pencil beam and we show the agreement with particle tracking calculations in the 3D magnetic field map. A new cyclotron based facility with this gantry will have a significantly smaller footprint, since one can refrain from the degrader and energy selection system behind the cyclotron. In the treatments, this gantry will enable a very fast proton beam delivery sequence, which may be of advantage for treatments in moving tissue.

preprint2015arXiv

Precise On-line Position Measurement for Particle Therapy

An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry$\hspace{0.5 mm}2$ at the Paul Scherrer Institute uses a strip ionization chamber for the on-line beam position verification. The design of the strip chamber placed in the beam in front of the patient allows for a small beam penumbra in order to achieve a high-quality lateral beam delivery. The position error of 1 mm in a lateral plane (plane perpendicular to the beam direction) can result in a dose inhomogeneity of more than $5 \%$. Therefore the goal of Gantry 2 commissioning was to reach a sub-millimeter level of the reconstruction accuracy in order to bring a dose uncertainty to a level of $1 \%$. In fact, we observed that for beams offered by Gantry 2 signal profiles in a lateral plane can be reconstructed with a precision of 0.1 mm. This is a necessary criterion to perform a reliable patient treatment. The front end electronics and the whole data processing sequence have been optimized for minimizing the dead time in between two consecutive spots to about 2 ms: the charge collection is performed in about 1 ms, read-out takes place in about 100 $μ$s while data verification and logging are completed in less than 1 ms.

preprint2001arXiv

A Fast High Resolution Track Trigger for the H1 Experiment

After 2001 the upgraded ep collider HERA will provide an about five times higher luminosity for the two experiments H1 and ZEUS. In order to cope with the expected higher event rates the H1 collaboration is building a track based trigger system, the Fast Track Trigger (FTT). It will be integrated in the first three levels (L1-L3) of the H1 trigger scheme to provide higher selectivity for events with charged particles. The FTT will allow to reconstruct 3-dimensional tracks in the central drift chamber down to 100 MeV/c within the L2 latency of ~ 23 mus. To reach the necessary momentum resolution of ~ 5% (at 1 GeV/c) sophisticated reconstruction algorithms have to be implemented using high density Field Programmable Gate Arrays (FPGA) and their embedded Content Addressable Memories (CAM). The final track parameter optimization will be done using non-iterative fits implemented in DSPs. While at the first trigger level rough track information will be provided, at L2 tracks with high resolution are available to form trigger decisions on topological and other track based criteria like multiplicities and momenta. At the third trigger level a farm of commercial processor boards will be used to compute physics quantities such as invariant masses.

preprint2001arXiv

A Multifunctional Processing Board for the Fast Track Trigger of the H1 Experiment

The electron-proton collider HERA is being upgraded to provide higher luminosity from the end of the year 2001. In order to enhance the selectivity on exclusive processes a Fast Track Trigger (FTT) with high momentum resolution is being built for the H1 Collaboration. The FTT will perform a 3-dimensional reconstruction of curved tracks in a magnetic field of 1.1 Tesla down to 100 MeV in transverse momentum. It is able to reconstruct up to 48 tracks within 23 mus in a high track multiplicity environment. The FTT consists of two hardware levels L1, L2 and a third software level. Analog signals of 450 wires are digitized at the first level stage followed by a quick lookup of valid track segment patterns. For the main processing tasks at the second level such as linking, fitting and deciding, a multifunctional processing board has been developed by the ETH Zurich in collaboration with Supercomputing Systems (Zurich). It integrates a high-density FPGA (Altera APEX 20K600E) and four floating point DSPs (Texas Instruments TMS320C6701). This presentation will mainly concentrate on second trigger level hardware aspects and on the implementation of the algorithms used for linking and fitting. Emphasis is especially put on the integrated CAM (content addressable memory) functionality of the FPGA, which is ideally suited for implementing fast search tasks like track segment linking.