Source author record

D. Masson

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

5works
6topics
4close collaborators

Published work

5 publications

preprint2022arXiv

Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of (360±60)(360 \pm 60) ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.

preprint2022arXiv

Double-Weak Decays of 124^{124}Xe and 136^{136}Xe in the XENON1T and XENONnT Experiments

We present results on the search for double-electron capture (2νECEC2ν\text{ECEC}) of 124^{124}Xe and neutrinoless double-ββ decay (0νββ0νββ) of 136^{136}Xe in XENON1T. We consider captures from the K- up to the N-shell in the 2νECEC2ν\text{ECEC} signal model and measure a total half-life of T1/22νECEC=(1.1±0.2stat±0.1sys)×1022  yrT_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr} with a 0.87  kg×yr0.87\;\text{kg}\times\text{yr} isotope exposure. The statistical significance of the signal is 7.0 σ7.0\,σ. We use XENON1T data with 36.16  kg×yr36.16\;\text{kg}\times\text{yr} of 136^{136}Xe exposure to search for 0νββ0νββ. We find no evidence of a signal and set a lower limit on the half-life of T1/20νββ>1.2×1024  yr  at  90 %  CLT_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to 0νββ0νββ. Assuming a 275  kg×yr275\;\text{kg}\times\text{yr} 136^{136}Xe exposure, the expected sensitivity is T1/20νββ>2.1×1025  yr  at  90 %  CLT_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}, corresponding to an effective Majorana mass range of ⟨mββ⟩<(0.19−0.59)  eV/c2\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2.

preprint2020arXiv

222^{222}Rn emanation measurements for the XENON1T experiment

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the 222^{222}Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a 222^{222}Rn activity concentration of 10 μμBq/kg in 3.2 t of xenon. The knowledge of the distribution of the 222^{222}Rn sources allowed us to selectively eliminate critical components in the course of the experiment. The predictions from the emanation measurements were compared to data of the 222^{222}Rn activity concentration in XENON1T. The final 222^{222}Rn activity concentration of (4.5 ±\pm 0.1) μμBq/kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.

preprint2020arXiv

Energy resolution and linearity of XENON1T in the MeV energy range

Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above ∼\sim200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of 136^{136}Xe at its QQ-value, Qββ≃Q_{ββ}\simeq 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 σ/μσ/μ is as low as (0.80±\pm0.02) % in its one-ton fiducial mass, and for single-site interactions at QββQ_{ββ}. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.

preprint2016arXiv

A low-mass dark matter search using ionization signals in XENON100

We perform a low-mass dark matter search using an exposure of 30\,kg×\timesyr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6\,GeV/c2c^2 above 1.4×10−411.4 \times 10^{-41}\,cm2^2 at 90\% confidence level.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.