Researcher profile

D. Hartill

D. Hartill contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

A temperature-mapping system for multi-cell SRF accelerating cavities

A Temperature mapping (T-map) system for Superconducting Radio Frequency (SRF) cavities consists of a thermometer array positioned precisely on an exterior cavity wall, capable of detecting small increases in temperature; therefore it is a powerful tool for research on the quality factor (Q0) of SRF cavities. A new multi-cell T-mapping system is has been developed at Cornell University. The system has nearly two thousand thermometers to cover 7-cell SRF cavities for Cornell ERL project. A new multiplexing scheme was adopted to reduce number of wires. A 1mK resolution of the temperature increase Delta T is achieved. A 9-cell cavity of TESLA geometry was tested with the T-map system. By converting Delta T to power loss and quality factor, it has been found that for this cavity, most surface losses were generated by the first cell when the accelerating gradient is increased above 15MV/m. The comparison of Q-value between with and without hotspots shows the heating on cavity wall degraded cavity Q0 about 1.65 times. The power loss on the hotspots is about 40% of the total power. Effective and intuitive ways of displaying surface properties of the cavity interior, e.g. the residual resistivity, will be shown.

preprint2014arXiv

Visible-light beam size monitors using synchrotron radiation at CESR

A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 um can be measured with a resolution of approximately 5 um. To measure larger beam size (> 500 um), direct imaging can be employed by rotating the double slits away from SR beam path. By imaging the pi-polarized component of SR, a small vertical beam size (~70 um) was measured during an undulator test run in CESR, which was consistent with the interferometer measurement. To measure the bunch length, a beam splitter is inserted to direct a fraction of light into a streak camera setup. This beam size monitor measures the transverse and longitudinal beam sizes simultaneously, which is successfully used for intrabeam scattering studies. Detailed error analysis is discussed.