preprint2015arXiv

A LEGO Watt Balance: An apparatus to determine a mass based on the new SI

A global effort to redefine our International System of Units (SI) is underway and the change to the new system is expected to occur in 2018. Within the newly redefined SI, the present base units will still exist but be derived from fixed numerical values of seven reference constants. More specifically, the unit of mass, the kilogram, will be realized through a fixed value of the Planck constant hh. For instance, a watt balance can be used to realize the kilogram unit of mass within a few parts in 10810^8. Such a balance has been designed and constructed at the National Institute of Standards and Technology. For educational outreach and to demonstrate the principle, we have constructed a LEGO tabletop watt balance capable of measuring a gram size mass to 1 % relative uncertainty. This article presents the design, construction, and performance of the LEGO watt balance and its ability to determine hh

preprint2015arXiv

A summary of the Planck constant measurements using a watt balance with a superconducting solenoid at NIST

Researchers at the National Institute of Standards and Technology have been using a watt balance, NIST-3, to measure the Planck constant hh for over ten years. Two recently published values disagree by more than one standard uncertainty. The motivation for the present manuscript is twofold. First, we correct the latest published number to take into account a recently discovered systematic error in mass dissemination at the Bureau International des Poids et Mesures (BIPM). Second, we provide guidance on how to combine the two numbers into one final result. In order to adequately reflect the discrepancy, we added an additional systematic uncertainty to the published uncertainty budgets. The final value of hh measured with NIST-3 is $h = 6.626\,069\,36(37)\times 10^{-34}\,\mbox{J\,s}$. This result is 77(57)×10−977(57) \times 10^{-9} fractionally higher than h90h_{\mathrm{90}}. Each number in parentheses gives the value of the standard uncertainty in the last two digits of the respective value and h90h_{\mathrm{90}} is the conventional value of the Planck constant given by h90≡4/(KJ−902RK−90)h_{\mathrm{90}}\equiv 4 /( K_{\mathrm{J-90}}^2 R_{\mathrm{K-90}}), where KJ−90K_{\mathrm{J-90}} and RK−90R_{\mathrm{K-90}} denote the conventional values of the Josephson and von Klitzing constants, respectively.

preprint2015arXiv

First measurements of the flux integral with the NIST-4 watt balance

In early 2014, construction of a new watt balance, named NIST-4, has started at the National Institute of Standards and Technology (NIST). In a watt balance, the gravitational force of an unknown mass is compensated by an electromagnetic force produced by a coil in a magnet system. The electromagnetic force depends on the current in the coil and the magnetic flux integral. Most watt balances feature an additional calibration mode, referred to as velocity mode, which allows one to measure the magnetic flux integral to high precision. In this article we describe first measurements of the flux integral in the new watt balance. We introduce measurement and data analysis techniques to assess the quality of the measurements and the adverse effects of vibrations on the instrument.

preprint2014arXiv

A determination of the local acceleration of gravity for the NIST-4 watt balance

A new watt balance is being constructed at the National Institute of Standards and Technology (NIST) in preparation for the redefinition of the International System of Units and the realization of mass through an exact value of the Planck constant. The total relative uncertainty goal for this instrument of a few parts in 10810^{8} requires that the local acceleration due to gravity be known at the location of a test mass with a relative uncertainty on the order of only a few parts in 10910^{9}. To make this determination, both the horizontal and vertical gradients of gravity must be known such that gravity may be tied from an absolute reference in the laboratory to the precise mass location. We describe the procedures used to model and measure gravity variations throughout the laboratory and give our results.