Source author record

D. Flores

D. Flores appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Inverse Low Gain Avalanche Detector (iLGAD) Periphery Design for X-Ray Applications

LGAD technology is established within the field of particle physics, as the baseline technology for the timing detectors of both the ATLAS and CMS upgrades at the HL-LHC. Pixelated LGADs have been proposed for the High Granularity Timing Detector (HGTD) and for the Endcap Timing Layer (ETL) of the ATLAS and CMS experiments, respectively. The drawback of segmenting an LGAD is the non-gain area between pixels and the consequent reduction in the fill factor. In this sense, inverse LGAD (iLGAD) technology has been proposed by IMB-CNM to enhance the fill factor and to reach excellent tracking capabilities. In this work, we explore the use of iLGAD sensors for X-Ray applications by developing a new generation of iLGADs. The periphery of the first iLGAD generation is optimized by means of TCAD tools, making them suitable for X-Ray irradiations thanks to the double side optimization. The fabricated iLGAD sensors exhibit good electrical performances before and after an X-Ray irradiation. The second iLGAD generation is able to withstand the same voltage, as contrary to the first iLGAD generation after irradiation.

preprint2019arXiv

Inverse Low Gain Avalanche Detectors (iLGADs) for precise tracking and timing applications

Low Gain Avalanche Detector (LGAD) is the baseline sensing technology of the recently proposed Minimum Ionizing Particle (MIP) end-cap timing detectors (MTD) at the Atlas and CMS experiments. The current MTD sensor is designed as a multi-pad matrix detector delivering a poor position resolution, due to the relatively large pad area, around 1 $mm^2$; and a good timing resolution, around 20-30 ps. Besides, in his current technological incarnation, the timing resolution of the MTD LGAD sensors is severely degraded once the MIP particle hits the inter-pad region since the signal amplification is missing for this region. This limitation is named as the LGAD fill-factor problem. To overcome the fill factor problem and the poor position resolution of the MTD LGAD sensors, a p-in-p LGAD (iLGAD) was introduced. Contrary to the conventional LGAD, the iLGAD has a non-segmented deep p-well (the multiplication layer). Therefore, iLGADs should ideally present a constant gain value over all the sensitive region of the device without gain drops between the signal collecting electrodes; in other words, iLGADs should have a 100${\%}$ fill-factor by design. In this paper, tracking and timing performance of the first iLGAD prototypes is presented.

preprint2015arXiv

Recent Technological Developments on LGAD and iLGAD Detectors for Tracking and Timing Applications

This paper reports the last technological development on the Low Gain Avalanche Detector (LGAD) and introduces a new architecture of these detectors called inverse-LGAD (iLGAD). Both approaches are based on the standard Avalanche Photo Diodes (APD) concept, commonly used in optical and X-ray detection applications, including an internal multiplication of the charge generated by radiation. The multiplication is inherent to the basic n++-p+-p structure, where the doping profile of the p+ layer is optimized to achieve high field and high impact ionization at the junction. The LGAD structures are optimized for applications such as tracking or timing detectors for high energy physics experiments or medical applications where time resolution lower than 30 ps is required. Detailed TCAD device simulations together with the electrical and charge collection measurements are presented through this work.