Researcher profile

Crystal E. Owens

Crystal E. Owens contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Computational Rheometry of Yielding and Viscoplastic Flow in Vane-and-Cup Rheometer Fixtures

A planar two-dimensional computational analysis is presented to qualify traditional and fractal vane-in-cup geometries for accurate rheometry of simple viscoplastic fluids with and without slip. Numerical simulations based on an adaptive augmented Lagrangian scheme are used to study the two-dimensional flow field of yield-stress fluids within and around vane tools with N=3 to 24 arms for a wide range of Bingham numbers, B (i.e. the ratio of the yield stress over the characteristic viscous stress). This allows for accurate calculations of the velocity and stress fields around vanes with various geometries, as well as direct comparison to experimental observations of the output torque measured by a rheometer, revealing sources of variation and error. We describe the impact of the vane structure on the fluid velocity field, from few-arm cruciform vanes (N < 6) that significantly perturb the flow away from ideal azimuthal kinematics, to many-arm fractal vanes (N > 12) in which the internal structural features are successfully ``cloaked&#34; by a yield surface. This results in the shearing of an almost-circular ring of viscoplastic fluid that is indistinguishable from the annular ring of fluid deformed around a slip-free rotating cylindrical bob and leads to more accurate rheometric measurements of the material flow curve. Moreover, in direct comparison with data from previous literature, we show that slip conditions on the vane surface do not impact the velocity field or measured overall torque T, whereas slip conditions on the smooth outer wall have significant impact on data, even when using a vane geometry. Finally, we describe the impact of vane topography and Bingham number, B, on the measured torque and rheometric accuracy of vane-in-cup geometries for ``simple&#34; (inelastic) yield-stress fluids described by either the Bingham plastic or Herschel-Bulkley constitutive model.

preprint2019arXiv

Improved Rheometry of Yield Stress Fluids Using Bespoke Fractal 3D Printed Vanes

To enable robust rheological measurements of the properties of yield stress fluids, we introduce a class of modified vane fixtures with fractal-like cross-sectional structures. A greater number of outer contact edges leads to increased kinematic homogeneity at the point of yielding and beyond. The vanes are 3D printed using a desktop stereolithography machine, making them inexpensive (disposable), chemically-compatible with a wide range of solvents, and readily adaptable as a base for further design innovations. To complete the tooling set, we introduce a textured 3D printed cup, which attaches to a standard rheometer base. We discuss general design criteria for 3D printed rheometer vanes, including consideration of sample volume displaced by the vanes, stress homogeneity, and secondary flows that constrain the parameter space of potential designs. We also develop a conversion from machine torque to material shear stress for vanes with an arbitrary number of arms. We compare a family of vane designs by measuring the viscosity of Newtonian calibration oils with error <5% relative to reference measurements made with a cone-and-plate geometry. We measure the flow curve of a simple Carbopol yield stress fluid, and show that a 24-arm 3D printed fractal vane agrees within 1% of reference measurements made with a roughened cone-and-plate geometry. Last, we demonstrate use of the 24-arm fractal vane to probe the thixo-elasto-visco-plastic (TEVP) response of a Carbopol-based hair gel, a jammed emulsion (mayonnaise), and a strongly alkaline carbon black-based battery slurry.

preprint2019arXiv

Interfacial Load Monitoring and Failure Detection in Total Joint Replacements via Piezoresistive Bone Cement and Electrical Impedance Tomography

Aseptic loosening, or loss of implant fixation, is a common complication following total joint replacement. Revision surgeries cost the healthcare system over $8 billion annually in the US. Despite the prevalence of aseptic loosening, timely and accurate detection remains a challenge because traditional imaging modalities such as plain radiographs struggle to reliably detect the early stages of implant loosening. Motivated by this challenge, we present a novel approach for in vivo monitoring and failure detection of cemented joint replacements. Poly(methyl methacrylate) (PMMA) bone cement is modified with low volume fractions of chopped carbon fiber (CF) to impart piezoresistive-based self-sensing. Electrical impedance tomography (EIT) is then used to detect and monitor load-induced deformation and fracture of CF/PMMA in a phantom tank. We therefore show that EIT indeed is able to adeptly detect loading force on a prosthetic surrogate, distinguish between increasing load magnitudes, detect failure of implant fixation, and even distinguish between cement cracking and cement de-bonding. Because EIT is a low-cost, physiologically benign, and potentially real-time imaging modality, the feasibility study herein presented has potential to transform the standard of care for post-operative monitoring of implant conditions. Beyond clinical relevance, this technique could positively impact orthopedic researchers by providing, via in vivo monitoring, insight into the factors that initiate aseptic loosening.