Researcher profile

Cristian D. Panda

Cristian D. Panda contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

High-sensitivity low-noise photodetector using large-area silicon photomultiplier

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs with large detection area have recently become commercially available, enabling applications where the photon flux is low both temporarily and spatially. On the other hand, several drawbacks exist in the usage of SiPMs such as a higher dark count rate, many readout channels, slow response time, and optical crosstalk; therefore, users need to carefully consider the trade-offs. This work presents a SiPM-embedded compact large-area photon detection module. Various techniques are adopted to overcome the disadvantages of SiPMs so that it can be generally utilized as an upgrade from a PMT. A simple cooling component and recently developed optical crosstalk suppression method are adopted to reduce the noise which is more serious for larger-area SiPMs. A dedicated readout circuit increases the response frequency and reduces the number of readout channels. We favorably compare this design with a conventional PMT and obtain both higher photon detection efficiency and larger-area acceptance.

preprint2022arXiv

Measurement of the H$^3Δ_1$ Radiative Lifetime in ThO

The best limit on the electron electric dipole moment (eEDM) comes from the ACME II experiment [Nature \textbf{562} (2018), 355-360] which probes physics beyond the Standard Model at energy scales well above 1 TeV. ACME II measured the eEDM by monitoring electron spin precession in a cold beam of the metastable H$^3Δ_1$ state of thorium monoxide (ThO) molecules, with an observation time $τ\approx 1$ ms for each molecule. We report here a new measurement of the lifetime of the ThO (H$^3Δ_1$) state, $τ_H = 4.2\pm 0.5$ ms. Using an apparatus within which $τ\approx τ_H$ will enable a substantial reduction in uncertainty of an eEDM measurement.

preprint2022arXiv

Snowmass 2021 White Paper: Tabletop experiments for infrared quantum gravity

Progress in the quantum readout and control of mechanical devices from single atoms to large masses may enable a first generation of experiments probing the gravitational interaction in the quantum regime, conceivably within the next decade. In this Snowmass whitepaper, we briefly outline the possibilities and challenges facing the realization of these experiments. In particular, we emphasize the need for detailed theories of modifications to the usual effective QFT of gravitons in the infrared regime $E/L^3 \ll m_{\rm Pl}/\ell_{\rm Pl}^3$ in which these experiments operate, and relations to possible UV completions.

preprint2020arXiv

Raman transitions driven by phase-modulated light in a cavity atom interferometer

Atom interferometers in optical cavities benefit from strong laser intensities and high-quality wavefronts. The laser frequency pairs that are needed for driving Raman transitions (often generated by phase modulating a monochromatic beam) form multiple standing waves in the cavity, resulting in a periodic spatial variation of the properties of the atom-light interaction along the cavity axis. Here, we model this spatial dependence and calculate two-photon Rabi frequencies and ac Stark shifts. We compare the model to measurements performed with varying cavity and pulse parameters such as cavity offset from the carrier frequency and the longitudinal position of the atom cloud. We show how setting cavity parameters to optimal values can increase the Raman transition efficiency at all positions in the cavity and nearly double the contrast in a Mach-Zehnder cavity atom interferometer in comparison to the unoptimized case.

preprint2019arXiv

Probing gravity by holding atoms for 20 seconds

Atom interferometers are powerful tools for both measurements in fundamental physics and inertial sensing applications. Their performance, however, has been limited by the available interrogation time of freely falling atoms in a gravitational field. We realize an unprecedented interrogation time of 20 seconds by suspending the spatially-separated atomic wavepackets in a lattice formed by the mode of an optical cavity. Unlike traditional atom interferometers, this approach allows potentials to be measured by holding, rather than dropping, atoms. After seconds of hold time, gravitational potential energy differences from as little as microns of vertical separation generate megaradians of interferometer phase. This trapped geometry suppresses the phase sensitivity to vibrations by 3-4 orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. Finally, we study the wavefunction dynamics driven by gravitational potential gradients across neighboring lattice sites.