Source author record

Clemens Weninger

Clemens Weninger appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Data acquisition from high-rate detectors at MAX IV

At MAX IV pixelated area detectors are operated at high frame rates to take advantage of the X-ray beam properties available from the fourth generation synchrotron in scattering, diffraction and imaging applications. A variety of photon counting and charge integrating detectors and sCMOS cameras have been integrated into a common data acquisition (DAQ) system in which data are streamed to a central Kubernetes cluster, mounting an IBM Storage Scale (GPFS) file system. The DAQ system provides live feedback from the detectors/cameras and extends to enable on-the-fly data processing. Control system integration via Tango provides a standardised single interface for controlling all DAQ components. Starting from an overview of the detector types in use, we describe the design and implementation of the MAX~IV detector-DAQ system and report a quantitative study of its performance in terms of data throughput and detector operating rates.

preprint2021arXiv

Generation of Intense Phase-Stable Femtosecond Hard X-ray Pulse Pairs

Coherent nonlinear spectroscopies and imaging in the X-ray domain provide direct insight into the coupled motions of electrons and nuclei with resolution on the electronic length and time scale. The experimental realization of such techniques will strongly benefit from access to intense, coherent pairs of femtosecond X-ray pulses. We have observed phase-stable X-ray pulse pairs containing more thank 3 x 10e7 photons at 5.9 keV (2.1 Angstrom) with about 1 fs duration and 2-5 fs separation. The highly directional pulse pairs are manifested by interference fringes in the superfluorescent and seeded stimulated manganese K-alpha emission induced by an X-ray free-electron laser. The fringes constitute the time-frequency X-ray analogue of the Young double-slit interference allowing for frequency-domain X-ray measurements with attosecond time resolution.