Source author record

Claudio Calosso

Claudio Calosso appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Frequency transfer via a two-way optical phase comparison on a multiplexed fiber network

We performed a two-way remote optical phase comparison on optical fiber. Two optical frequency signals were launched in opposite directions in an optical fiber and their phases were simultaneously measured at the other end. In this technique, the fiber noise was passively cancelled, and we compared two optical frequencies at the ultimate 1E-21 stability level. The experiment was performed on a 47 km fiber that is part of the metropolitan network for Internet traffic. The technique relies on the synchronous measurement of the optical phases at the two ends of the link, that is made possible by the use of digital electronics. This scheme offers several advantages with respect to active noise cancellation, and can be upgraded to perform more complex tasks.

preprint2011arXiv

Metrological characterization of the pulsed Rb clock with optical detection

We report on the implementation and the metrological characterization of a vapor-cell Rb frequency standard working in pulsed regime. The three main parts that compose the clock, physics package, optics and electronics, are described in detail in the paper. The prototype is designed and optimized to detect the clock transition in the optical domain. Specifically, the reference atomic transition, excited with a Ramsey scheme, is detected by observing the interference pattern on a laser absorption signal. \ The metrological analysis includes the observation and characterization of the clock signal and the measurement of frequency stability and drift. In terms of Allan deviation, the measured frequency stability results as low as $1.7\times 10^{-13} \ τ^{-1/2}$, $τ$ being the averaging time, and reaches the value of few units of $10^{-15}$ for $τ=10^{4}$ s, an unprecedent achievement for a vapor cell clock. We discuss in the paper the physical effects leading to this result with particular care to laser and microwave noises transferred to the clock signal. The frequency drift, probably related to the temperature, stays below $10^{-14}$ per day, and no evidence of flicker floor is observed. \ We also mention some possible improvements that in principle would lead to a clock stability below the $10^{-13}$ level at 1 s and to a drift of few units of $10^{-15}$ per day.