Researcher profile

Cishen Zhang

Cishen Zhang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2014arXiv

Parallel MRI Reconstruction by Convex Optimization

In parallel magnetic resonance imaging (pMRI), to find a joint solution for the image and coil sensitivity functions is a nonlinear and nonconvex problem. A class of algorithms reconstruct sensitivity encoded images of the coils first followed by the magnitude only image reconstruction, e.g. GRAPPA. It is shown in this paper that, if only the magnitude image is reconstructed, there exists a convex solution space for the magnitude image and sensitivity encoded images. This solution space enables formulation of a regularized convex optimization problem and leads to a globally optimal and unique solution for the magnitude image reconstruction. Its applications to in-vivo MRI data sets result in superior reconstruction performance compared with other algorithms.

preprint2013arXiv

A Convex Optimization Approach to pMRI Reconstruction

In parallel magnetic resonance imaging (pMRI) reconstruction without using estimation of coil sensitivity functions, one group of algorithms reconstruct sensitivity encoded images of the coils first followed by the magnitude only image reconstruction, e.g. GRAPPA, and another group of algorithms jointly compute the image and sensitivity functions by regularized optimization which is a non-convex problem with local only solutions. For the magnitude only image reconstruction, this paper derives a reconstruction formulation, which is linear in the magnitude image, and an associated convex hull in the solution space of the formulated equation containing the magnitude of the image. As a result, the magnitude only image reconstruction for pMRI is formulated into a two-step convex optimization problem, which has a globally optimal solution. An algorithm based on split-bregman and nuclear norm regularized optimizations is proposed to implement the two-step convex optimization and its applications to phantom and in-vivo MRI data sets result in superior reconstruction performance compared with other algorithms.

preprint2013arXiv

Robust Compressive Phase Retrieval via L1 Minimization With Application to Image Reconstruction

Phase retrieval refers to a classical nonconvex problem of recovering a signal from its Fourier magnitude measurements. Inspired by the compressed sensing technique, signal sparsity is exploited in recent studies of phase retrieval to reduce the required number of measurements, known as compressive phase retrieval (CPR). In this paper, l1 minimization problems are formulated for CPR to exploit the signal sparsity and alternating direction algorithms are presented for problem solving. For real-valued, nonnegative image reconstruction, the image of interest is shown to be an optimal solution of the formulated l1 minimization in the noise free case. Numerical simulations demonstrate that the proposed approach is fast, accurate and robust to measurements noises.

preprint2013arXiv

Sparse MRI for motion correction

MR image sparsity/compressibility has been widely exploited for imaging acceleration with the development of compressed sensing. A sparsity-based approach to rigid-body motion correction is presented for the first time in this paper. A motion is sought after such that the compensated MR image is maximally sparse/compressible among the infinite candidates. Iterative algorithms are proposed that jointly estimate the motion and the image content. The proposed method has a lot of merits, such as no need of additional data and loose requirement for the sampling sequence. Promising results are presented to demonstrate its performance.

preprint2012arXiv

Bayesian compressed sensing with new sparsity-inducing prior

Sparse Bayesian learning (SBL) is a popular approach to sparse signal recovery in compressed sensing (CS). In SBL, the signal sparsity information is exploited by assuming a sparsity-inducing prior for the signal that is then estimated using Bayesian inference. In this paper, a new sparsity-inducing prior is introduced and efficient algorithms are developed for signal recovery. The main algorithm is shown to produce a sparser solution than existing SBL methods while preserving their desirable properties. Numerical simulations with one-dimensional synthetic signals and two-dimensional images verify our analysis and show that for sparse signals the proposed algorithm outperforms its SBL peers in both the signal recovery accuracy and computational speed. Its improved performance is also demonstrated in comparison with other state-of-the-art methods in CS.