Source author record

Chrysostomos Valderanis

Chrysostomos Valderanis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

Construction of two large-size four-plane micromegas detectors

We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the resistive-strip technology and thus renders the detectors spark tolerant. Each quadruplet comprises four detection layers with 1024 readout strips and a strip pitch of 415 $μ$m. In two out of the four layers the strips are inclined by $\pm$1.5$^{\circ}$ to allow for the measurement of a second coordinate. We present the detector concept and report on the experience gained during the detector construction. In addition an evaluation of the detector performance with cosmic rays and test-beam data is given.

preprint2015arXiv

Development and Study of a Micromegas Pad-Detector for High Rate Applications

In this paper, the design and the performance of two prototype detectors based on Micromegas technology with a pad readout geometry is discussed. In addition, two alternative implementations of a spark-resistent protection layer on top of the readout pads have been tested to optimize the charge-up behavior of the detector under high rates. The prototype detectors consist of 500 pads with a size of 5x4 mm, each connected to one independent readout channel, and cover an active area of 10x10 cm. The design of these prototypes and its associated readout infrastructure was developed in such a way that it can be easily adapted for large-size detector concepts.

preprint2014arXiv

Signal Characteristics of a Resistive-Strip Micromegas Detector with an Integrated Two-Dimensional Readout

In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and high energy physics experiments. In this article, we present for the first time a systematic performance study of the signal characteristics of a resistive strip micromegas detector with a two-dimensional readout, based on test-beam and X-ray measurements. In particular, comparisons of the response of the two independent readout-layers regarding their signal shapes and signal reconstruction efficiencies are discussed.