Source author record

Christian J. Bordé

Christian J. Bordé appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2016arXiv

Reforming the international system of units: On our way to redefine the base units solely from fundamental constants and beyond

Our purpose is to offer a logical analysis of the system of units and to explore possible paths towards a consistent and unified system with an original perspective. The path taken here builds on the fact that, thanks to optical or matter-wave interferometry, any measurement can be reduced to a dimensionless phase measurement and we follow this simple guiding line. We finally show how one could progress even further on the path of a synthetic framework for fundamental metrology based upon pure geometry in five dimensions.

preprint2015arXiv

Accurate determination of the Boltzmann constant by Doppler spectroscopy: Towards a new definition of the kelvin

Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 $μ$m enables a determination of the Boltzmann constant k B. We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or speed-dependent collisional effects, we find that a determination of k B with an uncertainty of a few ppm is reachable. This is comparable to the best current uncertainty obtained using acoustic methods and would make a significant contribution to any new value of k B determined by the CODATA. Furthermore, having multiple independent measurements at these accuracies opens the possibility of defining the kelvin by fixing k B, an exciting prospect considering the upcoming redefinition of the International System of Units.

preprint2013arXiv

5D relativistic atom optics and interferometry

This contribution is an update of a previous presentation of 5D matter- wave optics and interferometry with a correction of some algebraic errors. Electromagnetic interactions are explicitly added in the 5D metric tensor in complete analogy with Kaluza's work. The 5D Lagrangian is rederived and an expression for the Hamiltonian suitable for the parabolic approximation is presented. The corresponding equations of motion are also given. The 5D action is shown to cancel for the actual trajectory which is a null geodesics of the 5D metric. This presentation is mainly devoted to the classical aspects of the theory and only general consequences for the quantum phase of matter-waves are outlined. The application to Bordé- Ramsey interferometers is given as an illustration.

preprint2012arXiv

Progress towards an accurate determination of the Boltzmann constant by Doppler spectroscopy

In this paper, we present significant progress performed on an experiment dedicated to the determination of the Boltzmann constant, k, by accurately measuring the Doppler absorption profile of a line in a gas of ammonia at thermal equilibrium. This optical method based on the first principles of statistical mechanics is an alternative to the acoustical method which has led to the unique determination of k published by the CODATA with a relative accuracy of 1.7 ppm. We report on the first measurement of the Boltzmann constant by laser spectroscopy with a statistical uncertainty below 10 ppm, more specifically 6.4 ppm. This progress results from improvements in the detection method and in the statistical treatment of the data. In addition, we have recorded the hyperfine structure of the probed saQ(6,3) rovibrational line of ammonia by saturation spectroscopy and thus determine very precisely the induced 4.36 (2) ppm broadening of the absorption linewidth. We also show that, in our well chosen experimental conditions, saturation effects have a negligible impact on the linewidth. Finally, we draw the route to future developments for an absolute determination of with an accuracy of a few ppm.

preprint2012arXiv

Reply to the comment on: "Does an atom interferometer test the gravitational redshift at the Compton frequency?"

Hohensee, Chu, Peters and Müller have submitted a comment (arXiv:1112.6039 [gr-qc]) on our paper "Does an atom interferometer test the gravitational redshift at the Compton frequency?", Classical and Quantum Gravity 28, 145017 (2011), arXiv:1009.2485 [gr-qc]. Here we reply to this comment and show that the main result of our paper, namely that atom interferometric gravimeters do not test the gravitational redshift at the Compton frequency, remains valid.

preprint2011arXiv

Atom interferometry and the Einstein equivalence principle

The computation of the phase shift in a symmetric atom interferometer in the presence of a gravitational field is reviewed. The difference of action-phase integrals between the two paths of the interferometer is zero for any Lagrangian which is at most quadratic in position and velocity. We emphasize that in a large class of theories of gravity the atom interferometer permits a test of the weak version of the equivalence principle (or universality of free fall) by comparing the acceleration of atoms with that of ordinary bodies, but is insensitive to that aspect of the equivalence principle known as the gravitational redshift or universality of clock rates.

preprint2011arXiv

Does an atom interferometer test the gravitational redshift at the Compton frequency ?

Atom interferometers allow the measurement of the acceleration of freely falling atoms with respect to an experimental platform at rest on Earth's surface. Such experiments have been used to test the universality of free fall by comparing the acceleration of the atoms to that of a classical freely falling object. In a recent paper, Müller, Peters and Chu [Nature {\bf 463}, 926-929 (2010)] argued that atom interferometers also provide a very accurate test of the gravitational redshift when considering the atom as a clock operating at the Compton frequency associated with the rest mass. We analyze this claim in the frame of general relativity and of different alternative theories. We show that the difference of "Compton phases" between the two paths of the interferometer is actually zero in a large class of theories, including general relativity, all metric theories of gravity, most non-metric theories and most theoretical frameworks used to interpret the violations of the equivalence principle. Therefore, in most plausible theoretical frameworks, there is no redshift effect and atom interferometers only test the universality of free fall. We also show that frameworks in which atom interferometers would test the redshift pose serious problems, such as (i) violation of the Schiff conjecture, (ii) violation of the Feynman path integral formulation of quantum mechanics and of the principle of least action for matter waves, (iii) violation of energy conservation, and more generally (iv) violation of the particle-wave duality in quantum mechanics. Standard quantum mechanics is no longer valid in such frameworks, so that a consistent interpretation of the experiment would require an alternative formulation of quantum mechanics. As such an alternative has not been proposed to date, we conclude that the interpretation of atom interferometers as testing the gravitational redshift is unsound.

preprint2011arXiv

Testing the Gravitational Redshift with Atomic Gravimeters?

Atom interferometers allow the measurement of the acceleration of freely falling atoms with respect to an experimental platform at rest on Earth's surface. Such experiments have been used to test the universality of free fall by comparing the acceleration of the atoms to that of a classical freely falling object. In a recent paper, Müller, Peters and Chu [Nature {\bf 463}, 926-929 (2010)] argued that atom interferometers also provide a very accurate test of the gravitational redshift (or universality of clock rates). Considering the atom as a clock operating at the Compton frequency associated with the rest mass, they claimed that the interferometer measures the gravitational redshift between the atom-clocks in the two paths of the interferometer at different values of gravitational potentials. In the present paper we analyze this claim in the frame of general relativity and of different alternative theories, and conclude that the interpretation of atom interferometers as testing the gravitational redshift at the Compton frequency is unsound. The present work is a summary of our extensive paper [Wolf et al., arXiv:1012.1194, Class. Quant. Grav. 28, 145017, (2011)], to which the reader is referred for more details.

preprint2011arXiv

The theory of quantum levitators

We develop a unified theory for clocks and gravimeters using the interferences of multiple atomic waves put in levitation by traveling light pulses. Inspired by optical methods, we exhibit a propagation invariant, which enables to derive analytically the wave function of the sample scattering on the light pulse sequence. A complete characterization of the device sensitivity with respect to frequency or to acceleration measurements is obtained. These results agree with previous numerical simulations and confirm the conjecture of sensitivity improvement through multiple atomic wave interferences. A realistic experimental implementation for such clock architecture is discussed.

preprint2009arXiv

A quantum trampoline for ultra-cold atoms

We have observed the interferometric suspension of a free-falling Bose-Einstein condensate periodically submitted to multiple-order diffraction by a vertical 1D standing wave. The various diffracted matter waves recombine coherently, resulting in high contrast interference in the number of atoms detected at constant height. For long suspension times, multiple-wave interference is revealed through a sharpening of the fringes. We use this scheme to measure the acceleration of gravity.

preprint2009arXiv

Determination of the Boltzmann constant by laser spectroscopy as a basis for future measurements of the thermodynamic temperature

In this paper, we present the latest results on the measurement of the Boltzmann constant kB, by laser spectroscopy of ammonia at 10 ?m. The Doppler absorption profile of a ro-vibrational line of an NH3 gas sample at thermal and pressure equilibrium is measured as accurately as possible. The absorption cell is placed inside a large 1m3 thermostat filled with an ice-water mixture, which sets the temperature very close to 273.15 K. Analysing this profile, which is related to the Maxwell-Boltzmann molecular speed distribution, leads to a determination of the Boltzmann constant via a measurement of the Doppler width (proportional tosqrt(kBT)). A spectroscopic determination of the Boltzmann constant with an uncertainty as low as 37 ppm is obtained. Recent improvements with a new passive thermostat lead to a temperature accuracy, stability and homogeneity of the absorption cell better than 1 ppm over a day.

preprint2009arXiv

Measurement of the Boltzmann constant by the Doppler broadening technique at a 3,8x10-5 accuracy level

In this paper, we describe an experiment performed at the Laboratoire de Physique des Lasers and dedicated to an optical measurement of the Boltzmann constant. With the proposed innovative technique, determining comes down to an ordinary frequency measurement. The method consists in measuring as accurately as possible the Doppler absorption profile of a rovibrational line of ammonia in thermal equilibrium. This profile is related to the Maxwell-Boltzmann molecular velocity distribution along the laser beam. A fit of the absorption line shape leads to a determination of the Doppler width proportional to sqrt(kT) and thus to a determination of the Boltzmann constant. The laser source is an ultra-stable CO2 laser with a wavelength . The absorption cell is placed in a thermostat keeping the temperature at 273.15 K within 1.4 mK. We were able to measure with a relative uncertainty as small as 3.8x10-5, which represents an improvement of an order of magnitude for an integration time comparable to our previous measurement published in 2007 [1]

preprint2007arXiv

First direct determination of the Boltzmann constant by an optical method

We have recorded the Doppler profile of a well-isolated rovibrational line in the \nu2 band of 14NH3. Ammonia gas was placed in an absorption cell thermalized by a water-ice bath. By extrapolating to zero pressure, we have deduced the Doppler width which gives a first measurement of the Boltzmann constant, kB, by laser spectroscopy. A relative uncertainty of 2x10-4 has been obtained. The present determination should be significantly improved in the near future and contribute to a new definition of the kelvin.