Researcher profile

Christian Boehm

Christian Boehm contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models

Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.

preprint2022arXiv

Diffuse ultrasound computed tomography for medical imaging

An alternative approach to ultrasound computed tomography (USCT) for medical imaging is proposed, with the intent to (i) shorten acquisition time for devices with a large number of emitters, (ii) eliminate the calibration step, and (iii) suppress instrument noise. Inspired by seismic ambient field interferometry, the method rests on the active excitation of diffuse ultrasonic wavefields and the extraction of deterministic travel time information by inter-station correlation. To reduce stochastic errors and accelerate convergence, ensemble interferograms are obtained by phase-weighted stacking of observed and computed correlograms, generated with identical realizations of random sources. Mimicking a breast imaging setup, the accuracy of the travel time measurements as a function of the number of emitters and random realizations can be assessed both analytically and with spectral-element simulations for realistic breast phantoms. The results warrant tomographic reconstructions with straight- or bent-ray approaches, where the effect of inherent stochastic fluctuations can be made significantly smaller than the effect of subjective choices on regularisation. This work constitutes a first conceptual study and a necessary prelude to future implementations.

preprint2020arXiv

Incorporating User's Preference into Attributed Graph Clustering

Graph clustering has been studied extensively on both plain graphs and attributed graphs. However, all these methods need to partition the whole graph to find cluster structures. Sometimes, based on domain knowledge, people may have information about a specific target region in the graph and only want to find a single cluster concentrated on this local region. Such a task is called local clustering. In contrast to global clustering, local clustering aims to find only one cluster that is concentrating on the given seed vertex (and also on the designated attributes for attributed graphs). Currently, very few methods can deal with this kind of task. To this end, we propose two quality measures for a local cluster: Graph Unimodality (GU) and Attribute Unimodality (AU). The former measures the homogeneity of the graph structure while the latter measures the homogeneity of the subspace that is composed of the designated attributes. We call their linear combination as Compactness. Further, we propose LOCLU to optimize the Compactness score. The local cluster detected by LOCLU concentrates on the region of interest, provides efficient information flow in the graph and exhibits a unimodal data distribution in the subspace of the designated attributes.