Source author record

Christer Gronlund

Christer Gronlund appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Domain Adaptation of Carotid Ultrasound Images using Generative Adversarial Network

Deep learning has been extensively used in medical imaging applications, assuming that the test and training datasets belong to the same probability distribution. However, a common challenge arises when working with medical images generated by different systems or even the same system with different parameter settings. Such images contain diverse textures and reverberation noise that violate the aforementioned assumption. Consequently, models trained on data from one device or setting often struggle to perform effectively with data from other devices or settings. In addition, retraining models for each specific device or setting is labor-intensive and costly. To address these issues in ultrasound images, we propose a novel Generative Adversarial Network (GAN)-based model. We formulated the domain adaptation tasks as an image-to-image translation task, in which we modified the texture patterns and removed reverberation noise in the test data images from the source domain to align with those in the target domain images while keeping the image content unchanged. We applied the proposed method to two datasets containing carotid ultrasound images from three different domains. The experimental results demonstrate that the model successfully translated the texture pattern of images and removed reverberation noise from the ultrasound images. Furthermore, we evaluated the CycleGAN approaches for a comparative study with the proposed model. The experimental findings conclusively demonstrated that the proposed model achieved domain adaptation (histogram correlation (0.960 (0.019), & 0.920 (0.043) and bhattacharya distance (0.040 (0.020), & 0.085 (0.048)), compared to no adaptation (0.916 (0.062) & 0.890 (0.077), 0.090 (0.070) & 0.121 (0.095)) for both datasets.

preprint2022arXiv

R2U++: A Multiscale Recurrent Residual U-Net with Dense Skip Connections for Medical Image Segmentation

U-Net is a widely adopted neural network in the domain of medical image segmentation. Despite its quick embracement by the medical imaging community, its performance suffers on complicated datasets. The problem can be ascribed to its simple feature extracting blocks: encoder/decoder, and the semantic gap between encoder and decoder. Variants of U-Net (such as R2U-Net) have been proposed to address the problem of simple feature extracting blocks by making the network deeper, but it does not deal with the semantic gap problem. On the other hand, another variant UNET++ deals with the semantic gap problem by introducing dense skip connections but has simple feature extraction blocks. To overcome these issues, we propose a new U-Net based medical image segmentation architecture R2U++. In the proposed architecture, the adapted changes from vanilla U-Net are: (1) the plain convolutional backbone is replaced by a deeper recurrent residual convolution block. The increased field of view with these blocks aids in extracting crucial features for segmentation which is proven by improvement in the overall performance of the network. (2) The semantic gap between encoder and decoder is reduced by dense skip pathways. These pathways accumulate features coming from multiple scales and apply concatenation accordingly. The modified architecture has embedded multi-depth models, and an ensemble of outputs taken from varying depths improves the performance on foreground objects appearing at various scales in the images. The performance of R2U++ is evaluated on four distinct medical imaging modalities: electron microscopy (EM), X-rays, fundus, and computed tomography (CT). The average gain achieved in IoU score is 1.5+-0.37% and in dice score is 0.9+-0.33% over UNET++, whereas, 4.21+-2.72 in IoU and 3.47+-1.89 in dice score over R2U-Net across different medical imaging segmentation datasets.