Researcher profile

Chris C. Shaw

Chris C. Shaw contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
2close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Feasibility of 2D antiscatter grid concept for flat panel detectors: preliminary investigation of primary transmission properties

Suppressing the effects of scattered radiation in flat panel detector, FPD, based CBCT still remains to be a challenge. To address the scatter problem, we have been investigating the feasibility of a two dimensional antiscatter grid (2D ASG) concept for FPDs. Although a 2D ASG can potentially provide high scatter rejection capability, primary transmission characteristics of a 2D ASG and its implications in image quality plays a more critical role in implementation of the 2D ASG concept. Thus, in this work, a computational model was developed to investigate the primary transmission properties of the 2D ASG for various grid and FPD pixel geometries, and the improvement in signal to noise ratio,SNR, was calculated analytically to demonstrate the impact of 2D ASG's transmission characteristics on image quality. Computational model showed that average primary transmission fraction (Tp) strongly depends on the septal thickness of 2D ASG, and 2D ASG can provide higher Tp than existing radiographic ASGs at a septal thickness of 0.1 mm. Due to the higher Tp, 2D ASG was also predicted to provide SNR improvements in projections in low to moderate scatter environments typically observed in CBCT imaging. On the other hand, the model also indicated that the shadow or footprint of the 2D ASG leads to spatially nonuniform variations in primary signal in FPD pixels. Reduction of septal thickness and optimization of 2D ASG's pitch may play an essential role in reducing such variations in primary image signal, and avoiding potential image artifacts associated with 2D ASG's footprint.