Researcher profile

Cem Altunbas

Cem Altunbas contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Concurrent kilovoltage CBCT imaging and megavoltage beam delivery: Suppression of cross-scatter with 2D antiscatter grids and grid-based scatter sampling

The concept of using kilovoltage (kV) and megavoltage (MV) beams concurrently has potential applications in cone beam computed tomography (CBCT) guided radiation therapy, such as single breath hold scans, metal artifact reduction, and simultaneous imaging during MV treatment delivery. However, MV cross-scatter generated during MV beam delivery degrades CBCT image quality. To address this, a 2D antiscatter grid and cross scatter correction method were investigated. a 3D printed, tungsten 2D antiscatter grid prototype was utilized to reduce MV cross-scatter fluence in kV projections during concurrent MV beam delivery. Remaining cross-scatter was corrected by using the 2D grid itself as a cross-scatter intensity sampling device, referred as Grid-based Scatter Sampling. To test this approach, kV CBCT acquisitions were performed while delivering 6 and 10 MV beams, mimicking high dose rate treatment delivery scenarios. MV cross-scatter suppression performance of the proposed approach was evaluated in projections and CBCT images of phantoms. 2D grid reduced the intensity of MV cross-scatter in kV projections by a factor of 3 on the average. Remaining MV cross-scatter estimated by Grid-based Scatter Sampling was within 7% of measured reference intensity values. CBCT image quality was improved substantially during concurrent kV-MV beam delivery. Median Hounsfield Unit (HU) inaccuracy was up to 191 HU without our methods, and it was reduced to 3 HU with our 2D grid and scatter correction approach. Our methods provided a factor of 2-6 improvement in contrast-to-ratio. Results indicate that our approach can successfully minimize the effects of high energy cross-scatter in concurrent kV CBCT imaging and megavoltage treatment delivery.

preprint2020arXiv

Feasibility of 2D antiscatter grid concept for flat panel detectors: preliminary investigation of primary transmission properties

Suppressing the effects of scattered radiation in flat panel detector, FPD, based CBCT still remains to be a challenge. To address the scatter problem, we have been investigating the feasibility of a two dimensional antiscatter grid (2D ASG) concept for FPDs. Although a 2D ASG can potentially provide high scatter rejection capability, primary transmission characteristics of a 2D ASG and its implications in image quality plays a more critical role in implementation of the 2D ASG concept. Thus, in this work, a computational model was developed to investigate the primary transmission properties of the 2D ASG for various grid and FPD pixel geometries, and the improvement in signal to noise ratio,SNR, was calculated analytically to demonstrate the impact of 2D ASG's transmission characteristics on image quality. Computational model showed that average primary transmission fraction (Tp) strongly depends on the septal thickness of 2D ASG, and 2D ASG can provide higher Tp than existing radiographic ASGs at a septal thickness of 0.1 mm. Due to the higher Tp, 2D ASG was also predicted to provide SNR improvements in projections in low to moderate scatter environments typically observed in CBCT imaging. On the other hand, the model also indicated that the shadow or footprint of the 2D ASG leads to spatially nonuniform variations in primary signal in FPD pixels. Reduction of septal thickness and optimization of 2D ASG's pitch may play an essential role in reducing such variations in primary image signal, and avoiding potential image artifacts associated with 2D ASG's footprint.