Source author record

Chih-Hsun Lin

Chih-Hsun Lin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

New approaches to particle induced prompt gamma imaging

The distribution of the prompt gamma emissions induced by proton interactions in a target material carries information concerning the proton range and target composition. In order to image prompt gamma we present different approaches. The first approach is based on knife-edge collimator utilized in tandem with a compact PET type detector in order to verify proton range by measuring the depth distribution of prompt gamma relying on Compton scattered events. A second approach aims at unambiguously identifying the presence of protons in a region of interest by introducing a bio-compatible fiducial marker in the patient and measuring the characteristic prompt gamma of the marker against background material. A third approach illustrates a novel design for position sensitive gamma imaging with a millimeter level adjustable position resolution with a high detection efficiency which is a step towards 3D prompt gamma imaging, useful to better understand the target composition. Simulations of the designs were performed using GATE/Geant4 Monte Carlo framework. Experimental tests on fiducial marker were conducted at the proton facilities in INER and Chang Gung Memorial hospital. Using the knife-edge PET approach a range verification of 0.7 mm can be achieved for shifts within 1 cm near the tumor region and up to 4 mm for shifts within a 4 cm window. For the fiducial marker approach we identify 984 keV as the dominant prompt gamma and show that for the 50% relative PG intensity, the R80 position falls within a 3 mm thick 48Ti marker. Using the position sensitive gamma imaging approach we present a feasible design to achieve spatial resolution values of 2.6 mm with a detection efficiency of 5.4E-6 at 6.1 MeV and up to eight depth positions in a single run. The relative advantage of these methods and the challenges in the implementation are discussed.

preprint2020arXiv

Feasibility of Observing Gamma-ray Polarization from Cygnus X-1 Using a CubeSat

Instruments flown on CubeSats are small. Meaningful applications of CubeSats in astronomical observations rely on the choice of a particular subject that is feasible for CubeSats. Here we report the result of a feasibility study for observing gamma-ray polarization from Cygnus X-1 using a small Compton polarimeter on board a 3U CubeSat. Silicon detectors and cerium bromide scintillators were employed in the instrument models that we discussed in this study. Through Monte Carlo simulations with Geant4-based MEGAlib package, we found that, with a 10-Ms on-axis, zenith-direction observation in a low inclination, low altitude earth orbit radiation background environment, the minimum detectable polarization degree can be down to about 10\% in 160 - 250 keV, 20\% in 250 - 400 keV, and 65\% in 400 - 2000 keV. A 3U CubeSat dedicated to observing Cygnus X-1 can therefore yield useful information on the polarization state of gamma-ray emissions from the brightest persistent X-ray black-hole binary in the sky.

preprint2010arXiv

Experimental and Theoretical Evidence for Extended Particle Models

We review the experimental searches on those interactions where the fundamental particles could exhibit a non point-like behavior. In particular we focus on the QED reaction measuring the differential cross sections for the process $ \EEGG $ at energies from sqrt{s} =55 GeV to 207 GeV using the data collected with the VENUS, TOPAZ, ALEPH, DELPHI L3 and OPAL from 1989 to 2003. The global fit to the data is 5 standard deviations away from the standard model expectation for the hypothesis of an excited state of the electron, corresponding to the cut-off scale Lambda =12.5 TeV. Assuming that this cut-off scale restricts the characteristic size of QED interaction to 15.7x10^{-18} cm, we perform an effort to assign in a semi-mechanical way all available properties of fundamental particles to a hypothetical classical object. Such object can be modeled as a classical gyroscope consisted of a non rotating inner massive kernel surrounded by an outer rotating massive layer equipped with charged sorted in a way to match the charge contents for different interactions. The model size of an electron agrees with 1.86x10^{-17} cm with the experiment. The introduction of a particle like structure related to gravity allows to estimate the inner mass kernel of an electron to 1.7x10^{-19} cm and the mass of a scaler to 154 GeV. The extension of the model to electrical charged particle-like structure in nonlinear electrodynamics coupled to General Relativity confirms the model in the global geometrical structure of mass and field distribution.