Source author record

Changgen Yang

Changgen Yang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

16works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

16 published item(s)

preprint2023arXiv

Imaging of muon track in CsI(Tl) crystal with single photon sensitive camera

As a novel approach on visual photon imaging by a single photon sensitive camera and PMTs, this work is trying to measure and identify muon tracks from the 2-D images of CsI(Tl) crystal (scintillator detectors). It is possible that muon tracks can be seen directly with a good signal-to-noise ratio neither with further amplification nor external light, which provides an evolution method for particle measurement in the photon-starved regime of scintillation detectors. The setup of the crystal and camera testing system and the identification algorithm of muon track will be discussed in detail including the system calibration, identification model, signal-to-noise ratio, muon track confirmation, and an expectation on further improvements and applications.

preprint2022arXiv

Imaging of CsI(Tl) crystal event and double-slit Young's interference by a single photon sensitive camera

We will discuss an imaging measurement with a single photon sensitive and low noise camera aiming to a new paradigm in the optical readout of scintillation detectors. The features of the single photon sensitive camera will be characterized and demonstrated with a measurement on double-slit Young's interference in single photon mode. An imaging test on CsI(Tl) crystal and alpha source will be performed further for preliminary measurements on the noise level and sensitivity of the system with a 1/2", f/1.4 lens, which reaches an sensitivity on light intensity around 1/10 of the 3-inch PMT and shows a potential to realize an imaging of single alpha event. An application proposal to scintillation detectors will be further discussed, where it is usually assumed that the imaging is not possible in such a photon-starved and large-emittance regime.

preprint2022arXiv

Mass Testing and Characterization of 20-inch PMTs for JUNO

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).

preprint2021arXiv

JUNO Physics and Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton LS detector at 700-m underground. An excellent energy resolution and a large fiducial volume offer exciting opportunities for addressing many important topics in neutrino and astro-particle physics. With 6 years of data, the neutrino mass ordering can be determined at 3-4 sigma and three oscillation parameters can be measured to a precision of 0.6% or better by detecting reactor antineutrinos. With 10 years of data, DSNB could be observed at 3-sigma; a lower limit of the proton lifetime of 8.34e33 years (90% C.L.) can be set by searching for p->nu_bar K^+; detection of solar neutrinos would shed new light on the solar metallicity problem and examine the vacuum-matter transition region. A core-collapse supernova at 10 kpc would lead to ~5000 IBD and ~2000 (300) all-flavor neutrino-proton (electron) scattering events. Geo-neutrinos can be detected with a rate of ~400 events/year. We also summarize the final design of the JUNO detector and the key R&D achievements. All 20-inch PMTs have been tested. The average photon detection efficiency is 28.9% for the 15,000 MCP PMTs and 28.1% for the 5,000 dynode PMTs, higher than the JUNO requirement of 27%. Together with the >20 m attenuation length of LS, we expect a yield of 1345 p.e. per MeV and an effective energy resolution of 3.02%/\sqrt{E (MeV)}$ in simulations. The underwater electronics is designed to have a loss rate <0.5% in 6 years. With degassing membranes and a micro-bubble system, the radon concentration in the 35-kton water pool could be lowered to <10 mBq/m^3. Acrylic panels of radiopurity <0.5 ppt U/Th are produced. The 20-kton LS will be purified onsite. Singles in the fiducial volume can be controlled to ~10 Hz. The JUNO experiment also features a double calorimeter system with 25,600 3-inch PMTs, a LS testing facility OSIRIS, and a near detector TAO.

preprint2020arXiv

Developing the radium measurement system for the water Cherenkov detector of the Jiangmen Underground Neutrino Observatory

The Jiangmen Underground Neutrino Observatory is proposed to determine neutrino mass hierarchy using a 20~ktonne liquid scintillator detector. Strict radio-purity requirements have been put forward for all the components of the detector. According to the MC simulation results, the radon dissolved in the water Cherenkov detector should be below 200~mBq/m$^3$. Radium, the progenitor of radon, should also be taken seriously into account. In order to measure the radium concentration in water, a radium measurement system, which consists of a radium extraction system, a radon emanation chamber and a radon concentration measurement system, has been developed. In this paper, the updated radon concentration in gas measurement system with a one-day-measurement sensitivity of $\sim$5~mBq/m$^3$, the detail of the development of the radium concentration in water measurement system with a sensitivity of $\sim$23~mBq/m$^3$ as well as the measurement results of Daya Bay water samples will be presented.

preprint2020arXiv

Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.

preprint2020arXiv

TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.

preprint2020arXiv

The liquid argon detector and measurement of SiPM array at liquid argon temperature

Particle detectors based on liquid argon (LAr) have recently become recognized as an extremely attractive technology for the direct detection of dark matter as well as the measurement of coherent elastic neutrino-nucleus scattering (CE$ν$NS). The Chinese argon group at Institute of High Energy Physics has been studying the LAr detector technology and a LAr detector has been operating steadily. A program of using a dual phase LAr detector to measure the CE$ν$NS at Taishang Nuclear Power Plant has been proposed and the R\&D work is ongoing. Considering the requirements of ultra-low radio-purity and high photon collection efficiency, SiPMs will be a good choice and will be used in the detector. In this proceeding, an introduction of the LAr detector and the measurement results of SiPM array at LAr temperature will be presented.

preprint2016arXiv

Neutron Beam Tests of $CsI(Na)$ and $CaF_{2}(Eu)$ Crystals for Dark Matter Direct Search

In recent decades, inorganic crystals have been widely used in dark matter direct search experiments. To contribute to the understanding of the capabilities of $CsI(Na)$ and $CaF_{2}(Eu)$ crystals, a mono-energetic neutron beam is utilized to study the properties of nuclear recoils, which are expected to be similar to signals of dark matter direct detection. The quenching factor of nuclear recoils in $CsI(Na)$ and $CaF_{2}(Eu)$, as well as an improved discrimination factor between nuclear recoils and $γ$ backgrounds in $CsI(Na)$, are reported.

preprint2016arXiv

Neutron Beam Tests of Barium Fluoride Crystal for Dark Matter Direct Detection

In order to test the capabilities of Barium Fluoride (BaF2) Crystal for dark matter direct detection, nuclear recoils are studied with mono-energetic neutron beam. The energy spectra of nuclear recoils, quenching factors for elastic scattering neutrons and discrimination capability between neutron inelastic scattering events and γ events are obtained for various recoil energies of the F content in BaF2.

preprint2015arXiv

A parametrization of the cosmic-ray muon flux at sea-level

Based on the standard Gaisser's formula, a modified parametrization for the sea-level cosmic-ray muon flux is introduced. The modification is verified against experimental results. The average vertical cosmic-ray muon intensity as a function of depth of standard rock is simulated using the modified formula as input to the MUSIC code. The calculated muon intensities is consistent with the experimental measurements.

preprint2015arXiv

Neutrino Physics with JUNO

The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hierarchy as a primary physics goal. It is also capable of observing neutrinos from terrestrial and extra-terrestrial sources, including supernova burst neutrinos, diffuse supernova neutrino background, geoneutrinos, atmospheric neutrinos, solar neutrinos, as well as exotic searches such as nucleon decays, dark matter, sterile neutrinos, etc. We present the physics motivations and the anticipated performance of the JUNO detector for various proposed measurements. By detecting reactor antineutrinos from two power plants at 53-km distance, JUNO will determine the neutrino mass hierarchy at a 3-4 sigma significance with six years of running. The measurement of antineutrino spectrum will also lead to the precise determination of three out of the six oscillation parameters to an accuracy of better than 1\%. Neutrino burst from a typical core-collapse supernova at 10 kpc would lead to ~5000 inverse-beta-decay events and ~2000 all-flavor neutrino-proton elastic scattering events in JUNO. Detection of DSNB would provide valuable information on the cosmic star-formation rate and the average core-collapsed neutrino energy spectrum. Geo-neutrinos can be detected in JUNO with a rate of ~400 events per year, significantly improving the statistics of existing geoneutrino samples. The JUNO detector is sensitive to several exotic searches, e.g. proton decay via the $p\to K^++\barν$ decay channel. The JUNO detector will provide a unique facility to address many outstanding crucial questions in particle and astrophysics. It holds the great potential for further advancing our quest to understanding the fundamental properties of neutrinos, one of the building blocks of our Universe.

preprint2015arXiv

Waterproofed Photomultiplier Tube Assemblies for the Daya Bay Reactor Neutrino Experiment

In the Daya Bay Reactor Neutrino Experiment 960 20-cm-diameter waterproof photomultiplier tubes are used to instrument three water pools as Cherenkov detectors for detecting cosmic-ray muons. Of these 960 photomultiplier tubes, 341 are recycled from the MACRO experiment. A systematic program was undertaken to refurbish them as waterproof assemblies. In the context of passing the water leakage check, a success rate better than 97% was achieved. Details of the design, fabrication, testing, operation, and performance of these waterproofed photomultiplier-tube assemblies are presented.

preprint2013arXiv

Advantages of Multiple Detectors for the Neutrino Mass Hierarchy Determination at Reactor Experiments

We study the advantages of a second identical detector at a medium baseline reactor neutrino experiment. A major obstruction to the determination of the neutrino mass hierarchy is the detector's unknown nonlinear energy response, which even under optimistic assumptions reduces the confidence in a hierarchy determination by about 1 sigma at a single detector experiment. Various energy response models are considered at one and two detector experiments with the same total target mass. A second detector at a sufficiently different baseline eliminates this 1 sigma reduction. Considering the unknown energy response, we find the confidence in a hierarchy determination at various candidate detector locations for JUNO and RENO 50. The best site for JUNO's near detector is under ZiLuoShan, 17 km and 66 km from the Yangjiang and Taishan reactor complexes respectively. We briefly describe other advantages, including a more precise determination of theta12 and the possibility of a DAEdALUS-inspired program to measure the CP-violating phase delta using a single pion source about 10 km from one detector and 20 km from the other. Two identical detectors provide a better energy resolution than a single (larger) detector, further increasing the confidence in a hierarchy determination.

preprint2012arXiv

Medium Baseline Reactor Neutrino Experiments with 2 Identical Detectors

In the next 10 years medium baseline reactor neutrino experiments will attempt to determine the neutrino mass hierarchy and to precisely measure θ_12. Both of these determinations will be more reliable if data from identical detectors at distinct baselines are combined. While interference effects can be eliminated by choosing detector sites orthogonal to the reactor arrays, one of the greatest challenges facing a determination of the mass hierarchy is the detector's unknown energy response. By comparing peaks at similar energies at two identical detectors at distinct baselines, one eliminates any correlated dependence upon a monotonic energy response. In addition, a second detector leads to new hierarchy-dependent observables, such as the ratio of the locations of the maxima of the Fourier cosine transforms. Simultaneously, one may determine the hierarchy by comparing the χ^2 best fits of ΔM^2_32 at the two detectors using the spectra associated to both hierarchies. A second detector at a distinct baseline also breaks the degeneracy between θ_12 and the background neutrino flux from, for example, distant reactors and increases the effective target mass, which is limited by current designs to about 20 kton/detector.

preprint2006arXiv

Measuring cosmogenic Li9 background in a reactor neutrino experiment

Cosmogenic isotopes 9Li and 8He produced in the detector are the most problematic background in the reactor neutrino experiments designed to determine precisely the neutrino mixing angle theta13. The average time interval of cosmic-ray muons in the detector is often on the order of the lifetimes of the 9Li and 8He isotopes. We have developed a method for determining this kind of background from the distribution of time since last muon for muon rate up to about 20 Hz when the background-to-signal ratio is small, on the order of a few percents.