Source author record

Chang Shin

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2010arXiv

Dynamical Decoupling of a single electron spin at room temperature

Here we report the increase of the coherence time T2_2 of a single electron spin at room temperature by using dynamical decoupling. We show that the Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence can prolong the T2_2 of a single Nitrogen-Vacancy center in diamond up to 2.44 ms compared to the Hahn echo measurement where T2=390μ_2 = 390 μs. Moreover, by performing spin locking experiments we demonstrate that with CPMG the maximum possible T2T_2 is reached. On the other hand, we do not observe strong increase of the coherence time in nanodiamonds, possibly due to the short spin lattice relaxation time T1=100μT_1=100 μs (compared to T1_1 = 5.93 ms in bulk). An application for detecting low magnetic field is demonstrated, where we show that the sensitivity using the CPMG method is improved by about a factor of two compared to the Hahn echo method.

preprint2010arXiv

Sub-optical resolution of single spins using magnetic resonance imaging at room temperature in diamond

There has been much recent interest in extending the technique of magnetic resonance imaging (MRI) down to the level of single spins with sub-optical wavelength resolution. However, the signal to noise ratio for images of individual spins is usually low and this necessitates long acquisition times and low temperatures to achieve high resolution. An exception to this is the nitrogen-vacancy (NV) color center in diamond whose spin state can be detected optically at room temperature. Here we apply MRI to magnetically equivalent NV spins in order to resolve them with resolution well below the optical wavelength of the readout light. In addition, using a microwave version of MRI we achieved a resolution that is 1/270 size of the coplanar striplines, which define the effective wavelength of the microwaves that were used to excite the transition. This technique can eventually be extended to imaging of large numbers of NVs in a confocal spot and possibly to image nearby dark spins via their mutual magnetic interaction with the NV spin.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.