Researcher profile

Cathal Gurrin

Cathal Gurrin contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

The State-of-the-Art in Lifelog Retrieval: A Review of Progress at the ACM Lifelog Search Challenge Workshop 2022-24

The ACM Lifelog Search Challenge (LSC) is a venue that welcomes and compares systems that support the exploration of lifelog data, and in particular the retrieval of specific information, through an interactive competition format. This paper reviews the recent advances in interactive lifelog retrieval as demonstrated at the ACM LSC from 2022 to 2024. Through a detailed comparative analysis, we highlight key improvements across three main retrieval tasks: known-item search, question answering, and ad-hoc search. Our analysis identifies trends such as the widespread adoption of embedding-based retrieval methods (e.g., CLIP, BLIP), increased integration of large language models (LLMs) for conversational retrieval, and continued innovation in multimodal and collaborative search interfaces. We further discuss how specific retrieval techniques and user interface (UI) designs have impacted system performance, emphasizing the importance of balancing retrieval complexity with usability. Our findings indicate that embedding-driven approaches combined with LLMs show promise for lifelog retrieval systems. Likewise, improving UI design can enhance usability and efficiency. Additionally, we recommend reconsidering multi-instance system evaluations within the expert track to better manage variability in user familiarity and configuration effectiveness.

preprint2025arXiv

The CASTLE 2024 Dataset: Advancing the Art of Multimodal Understanding

Egocentric video has seen increased interest in recent years, as it is used in a range of areas. However, most existing datasets are limited to a single perspective. In this paper, we present the CASTLE 2024 dataset, a multimodal collection containing ego- and exo-centric (i.e., first- and third-person perspective) video and audio from 15 time-aligned sources, as well as other sensor streams and auxiliary data. The dataset was recorded by volunteer participants over four days in a fixed location and includes the point of view of 10 participants, with an additional 5 fixed cameras providing an exocentric perspective. The entire dataset contains over 600 hours of UHD video recorded at 50 frames per second. In contrast to other datasets, CASTLE 2024 does not contain any partial censoring, such as blurred faces or distorted audio. The dataset is available via https://castle-dataset.github.io/.

preprint2023arXiv

HADA: A Graph-based Amalgamation Framework in Image-text Retrieval

Many models have been proposed for vision and language tasks, especially the image-text retrieval task. All state-of-the-art (SOTA) models in this challenge contained hundreds of millions of parameters. They also were pretrained on a large external dataset that has been proven to make a big improvement in overall performance. It is not easy to propose a new model with a novel architecture and intensively train it on a massive dataset with many GPUs to surpass many SOTA models, which are already available to use on the Internet. In this paper, we proposed a compact graph-based framework, named HADA, which can combine pretrained models to produce a better result, rather than building from scratch. First, we created a graph structure in which the nodes were the features extracted from the pretrained models and the edges connecting them. The graph structure was employed to capture and fuse the information from every pretrained model with each other. Then a graph neural network was applied to update the connection between the nodes to get the representative embedding vector for an image and text. Finally, we used the cosine similarity to match images with their relevant texts and vice versa to ensure a low inference time. Our experiments showed that, although HADA contained a tiny number of trainable parameters, it could increase baseline performance by more than 3.6% in terms of evaluation metrics in the Flickr30k dataset. Additionally, the proposed model did not train on any external dataset and did not require many GPUs but only 1 to train due to its small number of parameters. The source code is available at https://github.com/m2man/HADA.

preprint2022arXiv

An Improved Subject-Independent Stress Detection Model Applied to Consumer-grade Wearable Devices

Stress is a complex issue with wide-ranging physical and psychological impacts on human daily performance. Specifically, acute stress detection is becoming a valuable application in contextual human understanding. Two common approaches to training a stress detection model are subject-dependent and subject-independent training methods. Although subject-dependent training methods have proven to be the most accurate approach to build stress detection models, subject-independent models are a more practical and cost-efficient method, as they allow for the deployment of stress level detection and management systems in consumer-grade wearable devices without requiring training data for the end-user. To improve the performance of subject-independent stress detection models, in this paper, we introduce a stress-related bio-signal processing pipeline with a simple neural network architecture using statistical features extracted from multimodal contextual sensing sources including Electrodermal Activity (EDA), Blood Volume Pulse (BVP), and Skin Temperature (ST) captured from a consumer-grade wearable device. Using our proposed model architecture, we compare the accuracy between stress detection models that use measures from each individual signal source, and one model employing the fusion of multiple sensor sources. Extensive experiments on the publicly available WESAD dataset demonstrate that our proposed model outperforms conventional methods as well as providing 1.63% higher mean accuracy score compared to the state-of-the-art model while maintaining a low standard deviation. Our experiments also show that combining features from multiple sources produce more accurate predictions than using only one sensor source individually.

preprint2022arXiv

Analysing the Performance of Stress Detection Models on Consumer-Grade Wearable Devices

Identifying stress levels can provide valuable data for mental health analytics as well as labels for annotation systems. Although much research has been conducted into stress detection models using heart rate variability at a higher cost of data collection, there is a lack of research on the potential of using low-resolution Electrodermal Activity (EDA) signals from consumer-grade wearable devices to identify stress patterns. In this paper, we concentrate on performing statistical analyses on the stress detection capability of two popular approaches of training stress detection models with stress-related biometric signals: user-dependent and user-independent models. Our research manages to show that user-dependent models are statistically more accurate for stress detection. In terms of effectiveness assessment, the balanced accuracy (BA) metric is employed to evaluate the capability of distinguishing stress and non-stress conditions of the models trained on either low-resolution or high-resolution Electrodermal Activity (EDA) signals. The results from the experiment show that training the model with (comparatively low-cost) low-resolution EDA signal does not affect the stress detection accuracy of the model significantly compared to using a high-resolution EDA signal. Our research results demonstrate the potential of attaching the user-dependent stress detection model trained on personal low-resolution EDA signal recorded to collect data in daily life to provide users with personal stress level insight and analysis.