Source author record

Cary Zeitlin

Cary Zeitlin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Measurements of the neutral particle spectra on Mars by MSL/RAD from 2015-11-15 to 2016-01-15

The Radiation Assessment Detector (RAD), onboard the Mars Science Laboratory (MSL) rover Curiosity, has been measuring the energetic charged and neutral particles and the radiation dose rate on the surface of Mars since the landing of the rover in August 2012. In contrast to charged particles, neutral particles (neutrons and gamma-rays) are measured indirectly: the energy deposition spectra produced by neutral particles are complex convolutions of the incident particle spectra with the detector response functions. An inversion technique has been developed and applied to jointly unfold the deposited energy spectra measured in two scintillators of different types (CsI for high gamma detection efficiency, and plastic for neutrons) to obtain the neutron and gamma-ray spectra. This result is important for determining the biological impact of the Martian surface radiation contributed by neutrons, which interact with materials differently from the charged particles. These first in-situ measurements on Mars provide (1) an important reference for assessing the radiation-associated health risks for future manned missions to the red planet and (2) an experimental input for validating the particle transport codes used to model the radiation environments within spacecraft or on the surface of planets. Here we present neutral particle spectra as well as the corresponding dose and dose equivalent rates derived from RAD measurement during a period (November 15, 2015 to January 15, 2016) for which the surface particle spectra have been simulated via different transport models.

preprint2020arXiv

The pivot energy of Solar Energetic Particles Affecting the Martian surface radiation environment

Space radiation is a major risk for humans, especially on long-duration missions to outer space, e.g., a manned mission to Mars. Galactic cosmic rays (GCR) contribute a predictable radiation background, the main risk is due to the highly variable and currently unpredictable flux of solar energetic particles (SEPs). Such sporadic SEP events may induce acute health effects and are thus considered a critical mission risk for future human exploration of Mars. Therefore, it is of utmost importance to study, model, and predict the surface radiation environment during such events. It is well known that the deep-space SEP differential energy spectrum at high energies is often given by a power law. We use a measurement-validated particle transport code to show that, for large SEP events with proton energy extending above ~ 500 MeV with a power-law distribution, it is sufficient to measure the SEP flux at a pivot energy of ~ 300 MeV above the Martian atmosphere to predict the dose rate on the Martian surface. In conjunction with a validation by in-situ measurements from the Martian surface, this remarkable simplification and elegant quantification could enable instant predictions of the radiation environment on the surface of Mars upon the onset of large SEP events.

preprint2015arXiv

Modeling the variations of Dose Rate measured by RAD during the first MSL Martian year: 2012-2014

The Radiation Assessment Detector (RAD), on board Mars Science Laboratory's (MSL) rover Curiosity, measures the {energy spectra} of both energetic charged and neutral particles along with the radiation dose rate at the surface of Mars. With these first-ever measurements on the Martian surface, RAD observed several effects influencing the galactic cosmic ray (GCR) induced surface radiation dose concurrently: [a] short-term diurnal variations of the Martian atmospheric pressure caused by daily thermal tides, [b] long-term seasonal pressure changes in the Martian atmosphere, and [c] the modulation of the primary GCR flux by the heliospheric magnetic field, which correlates with long-term solar activity and the rotation of the Sun. The RAD surface dose measurements, along with the surface pressure data and the solar modulation factor, are analysed and fitted to empirical models which quantitatively demonstrate} how the long-term influences ([b] and [c]) are related to the measured dose rates. {Correspondingly we can estimate dose rate and dose equivalents under different solar modulations and different atmospheric conditions, thus allowing empirical predictions of the Martian surface radiation environment.

preprint2015arXiv

Variations of dose rate observed by MSL/RAD in transit to Mars

Aims: To predict the cruise radiation environment related to future human missions to Mars, the correlation between solar modulation potential and the dose rate measured by the Radiation Assessment Detector (RAD) has been analyzed and empirical models have been employed to quantify this correlation. Methods: The instrument RAD, onboard Mars Science Laboratory's (MSL) rover Curiosity, measures a broad spectrum of energetic particles along with the radiation dose rate during the 253-day cruise phase as well as on the surface of Mars. With these first ever measurements inside a spacecraft from Earth to Mars, RAD observed the impulsive enhancement of dose rate during solar particle events as well as a gradual evolution of the galactic cosmic ray (GCR) induced radiation dose rate due to the modulation of the primary GCR flux by the solar magnetic field, which correlates with long-term solar activities and heliospheric rotation. Results: We analyzed the dependence of the dose rate measured by RAD on solar modulation potentials and estimated the dose rate and dose equivalent under different solar modulation conditions. These estimations help us to have approximate predictions of the cruise radiation environment, such as the accumulated dose equivalent associated with future human missions to Mars. Conclusions: The predicted dose equivalent rate during solar maximum conditions could be as low as one-fourth of the current RAD cruise measurement. However, future measurements during solar maximum and minimum periods are essential to validate our estimations.