Researcher profile

C. Wiseman

C. Wiseman contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
13works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2023arXiv

Modeling Backgrounds for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay ($0νββ$) experiment containing $\sim$30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and $\sim$14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the $0νββ$ Q-value, 15.7 $\pm$ 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

preprint2022arXiv

$α$-event Characterization and Rejection in Point-Contact HPGe Detectors

P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.

preprint2022arXiv

Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $γ$-rays emitted from the excited $^{16}$O states that are populated when the incoming $α$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($α,n$)-reactions in future double-beta decay search efforts.

preprint2022arXiv

Search for solar axions via axion-photon coupling with the Majorana Demonstrator

Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium detectors using a 33 kg-yr exposure collected between Jan. 2017 and Nov. 2019. A temporal-energy analysis gives a new limit on the axion-photon coupling as $g_{aγ}<1.45\times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axions with mass up to 100 eV/$c^2$. This improves laboratory-based limits between about 1 eV/$c^2$ and 100 eV/$c^2$.

preprint2022arXiv

The COHERENT Experimental Program

The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world&#39;s first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT&#39;s ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.

preprint2022arXiv

The MAJORANA DEMONSTRATOR Readout Electronics System

The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

preprint2022arXiv

Variable Energy X-ray Fluorescence Source

We detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8$\times10^6$~dpm) \nuc{99}{Tc} $β$ source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as \textsc{Majorana} and LEGEND.

preprint2021arXiv

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.

preprint2021arXiv

Signatures of muonic activation in the Majorana Demonstrator

Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10$^{28}$ years half-life with background rates of 10$^{-5}$cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data is used to search for decay signatures of meta-stable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations, and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in $^{76}$Ge.

preprint2021arXiv

The Majorana Demonstrator&#39;s Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

The Majorana Demonstrator is a neutrinoless double-beta decay search consisting of a low-background modular array of high-purity germanium detectors, $\sim2/3$ of which are enriched to 88\% in $^{76}$Ge. The experiment is also searching for double-beta decay of $^{76}$Ge to excited states (e.s.) in $^{76}$Se. $^{76}$Ge can decay into three daughter states of $^{76}$Se, with clear event signatures consisting of a $ββ$-decay followed by the prompt emission of one or two $γ$-rays. This results with high probability in multi-detector coincidences. The granularity of the Demonstrator detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9~kg-y of isotopic exposure, the Demonstrator has set world leading limits for each e.s.\ decay of $^{76}$Ge, with 90\% CL lower half-life limits in the range of $(0.75-4.0)\times10^{24}$~y. In particular, for the $2ν$ transition to the first $0^+$ e.s.\ of $^{76}$Se, a lower half-life limit of $7.5\times10^{23}$~y at 90\% CL was achieved.

preprint2020arXiv

COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon

Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of &#34;Analysis A&#34; published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both &#34;signal&#34; and &#34;backgrounds&#34; along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.

preprint2019arXiv

A Low Energy Rare Event Search with the Majorana Demonstrator

The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy threshold, including bosonic dark matter, solar axions, and lightly ionizing particles. In this analysis, a novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of pulse shape analysis cuts, and we present updated bosonic dark matter and solar axion results from an 11.17 kg-y dataset using a 5 keV analysis threshold.

preprint2019arXiv

Results of the MAJORANA DEMONSTRATOR&#39;s Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of $^{76}$Ge to excited states (E.S.) in $^{76}$Se using a modular array of high purity Germanium detectors. $^{76}$Ge can decay into three E.S.s of $^{76}$Se. The E.S. decays have a clear event signature consisting of a $ββ$-decay with the prompt emission of one or two $γ$-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of $(0.56-2.1)\cdot10^{24}$ y. In particular, for the $2ν$ transition to the first $0^+$ E.S. of $^{76}$Se, a lower half-life limit of $0.68\cdot10^{24}$ at 90% CL was achieved.