Source author record

C. Vidal

C. Vidal appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2023arXiv

Two-Photon EXchange -- TPEX

We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of $2.12\times10^{35}$~cm$^{-2}\cdot$s$^{-1}\cdot$sr$^{-1}$ ($\sim200$ times the luminosity achieved by OLYMPUS). A commissioning run at 2 GeV followed by measurements at 3 GeV would provide new data up to $Q^2=4.6$~(GeV/$c$)$^2$ (twice the range of current measurements). Lead tungstate calorimeters would be used to detect the scattered leptons at polar angles of $30^\circ$, $50^\circ$, $70^\circ$, $90^\circ$, and $110^\circ$. The measurements could be scheduled to not interfere with the operation of PETRA. We present rate estimates and simulations for the planned measurements including background considerations. Initial measurements at the DESY test beam facility using prototype lead tungstate calorimeters in 2019, 2021, and 2022 were made to check the Monte Carlo simulations and the performance of the calorimeters. These tests also investigated different readout schemes (triggered and streaming). Various upgrades are possible to shorten the running time and to make higher beam energies and thus greater $Q^2$ ranges accessible.

preprint2022arXiv

Searching for New Physics with DarkLight at the ARIEL Electron-Linac

The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/$c^2$. The proposed DarkLight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV e$^+$e$^-$ invariant mass range. This proceeding will focus on the experimental design and physics case of the DarkLight experiment.

preprint2019arXiv

Measurement of Moller Scattering at 2.5 MeV

Moller scattering is one of the most fundamental processes in QED. Understanding it to high precision is necessary for a variety of modern nuclear and particle physics experiments. In a recent calculation, existing soft-photon radiative corrections were combined with new hard-photon bremsstrahlung calculations to take into account the effect of photon emission at any photon energy, where the electron mass was included at all steps. To test the calculation, an experiment was carried out using the 3 MV Van de Graaff electrostatic accelerator at the MIT High Voltage Research Laboratory. Momentum spectra at three scattering angles at an incident electron energy of 2.5 MeV are reported here, and compared to the simulated radiative Moller spectra, based on our previous calculation. Good agreement between the measurements and our calculation is observed in the momentum spectrum at the three angles.

preprint2019arXiv

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

preprint2016arXiv

Precision Electron-Beam Polarimetry using Compton Scattering at 1 GeV

We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micro-strip detector which was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector and its large acceptance. The polarization of the $180~μ$A, $1.16$~GeV electron beam was measured with a statistical precision of $<$~1\% per hour and a systematic uncertainty of 0.59\%. This exceeds the level of precision required by the \qweak experiment, a measurement of the vector weak charge of the proton. Proposed future low-energy experiments require polarization uncertainty $<$~0.4\%, and this result represents an important demonstration of that possibility. This measurement is also the first use of diamond detectors for particle tracking in an experiment.

preprint2014arXiv

The DarkLight Experiment: A Precision Search for New Physics at Low Energies

We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac incident on a windowless gas target of molecular hydrogen. The complete final state including scattered electron, recoil proton, and e+e- pair will be detected. A phase-I experiment has been funded and is expected to take data in the next eighteen months. The complete phase-II experiment is under final design and could run within two years after phase-I is completed. The DarkLight experiment drives development of new technology for beam, target, and detector and provides a new means to carry out electron scattering experiments at low momentum transfers.

preprint2013arXiv

DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility

We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.

preprint2013arXiv

The OLYMPUS Experiment

The OLYMPUS experiment was designed to measure the ratio between the positron-proton and electron-proton elastic scattering cross sections, with the goal of determining the contribution of two-photon exchange to the elastic cross section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, $μ_p G^p_E/G^p_M$, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01~GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately $25^\circ$--$75^\circ$. Symmetric Møller/Bhabha calorimeters at $1.29^\circ$ and telescopes of GEM and MWPC detectors at $12^\circ$ served as luminosity monitors. A total luminosity of approximately 4.5~fb$^{-1}$ was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.