Source author record

C. R. Locke

C. R. Locke appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2006arXiv

Long Term Operation and Performance of Cryogenic Sapphire Oscillators

Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.

preprint2002arXiv

Properties of a monolithic sapphire parametric transducer: prospects of measuring the standard quantum limit

To measure the standard quantum limit (SQL) a high quality transducer must be coupled to a high quality mechanical system. Due to its monolithic nature, the monolithic sapphire transducer (MST) has high quality factors for both types of resonances. Single loop suspension is shown to yield a mechanical quality factor of 6.10^8 at 4 K. From standard analysis we show the MST has the potential to measure noise fluctuations of the mechanical oscillator at the SQL. also, we point out a new way to determine if the transducer back action is quantum limited. We show that if the fluctuations are at the quantum limit, then the amplitude of the oscillation will be amplified by the ratio of the ringdown time to the measurement time, which is an inherently easier measurement.