Source author record

C. Petitjean

C. Petitjean appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

Search for the muon electric dipole moment using frozen-spin technique at PSI

The presence of a permanent electric dipole moment in an elementary particle implies Charge-Parity symmetry violation and thus could help explain the matter-antimatter asymmetry observed in our universe. Within the context of the Standard Model, the electric dipole moment of elementary particles is extremely small. However, many Standard Model extensions such as supersymmetry predict large electric dipole moments. Recently, the muon electric dipole moment has become a topic of particular interest due to the tensions in the magnetic anomaly of the muon and the electron, and hints of lepton-flavor universality violation in B-meson decays. In this article, we discuss a dedicated effort at the Paul Scherrer Institute in Switzerland to search for the muon electric dipole moment using a 3-T compact solenoid storage ring and the frozen-spin technique. This technique could reach a sensitivity of $6\times10^{-23}$ $e\cdot$cm after a year of data taking with the $p=125$ MeV/$c$ muon beam at the Paul Scherrer Institute. This allows us to probe various Standard Model extensions not reachable by traditional searches using muon $g-2$ storage rings.

preprint2019arXiv

muCool: A novel low-energy muon beam for future precision experiments

Experiments with muons ($μ^{+}$) and muonium atoms ($μ^{+}e^{-}$) offer several promising possibilities for testing fundamental symmetries. Examples of such experiments include search for muon electric dipole moment, measurement of muon $g-2$ and experiments with muonium from laser spectroscopy to gravity experiments. These experiments require high quality muon beams with small transverse size and high intensity at low energy. At the Paul Scherrer Institute, Switzerland, we are developing a novel device that reduces the phase space of a standard $μ^{+}$ beam by a factor of $10^{10}$ with $10^{-3}$ efficiency. The phase space compression is achieved by stopping a standard $μ^{+}$ beam in a cryogenic helium gas. The stopped $μ^{+}$ are manipulated into a small spot with complex electric and magnetic fields in combination with gas density gradients. From here, the muons are extracted into the vacuum and into a field-free region. Various aspects of this compression scheme have been demonstrated. In this article the current status will be reported.

preprint2018arXiv

muCool: A next step towards efficient muon beam compression

A novel device to compress the phase space of a muon beam by a factor of $10^{10}$ with a $10^{-3}$ efficiency is under development. A surface muon beam is stopped in a helium gas target consisting of several compression stages, wherein strong electric and magnetic fields are applied. The spatial extent of the stopped muon swarm is decreased by means of these fields until muons with eV energy are extracted into vacuum through a small orifice. It was measured that a 20 cm long muon stop distribution can be compressed in longitudinal direction to sub-mm extent within 2 ${\rm μs}$. Additionally, a drift perpendicular to the magnetic field of the compressed low-energy muon swarm was successfully demonstrated, paving the way towards the extraction from the gas and re-acceleration of the muons.

preprint2015arXiv

Measurement of the Formation Rate of Muonic Hydrogen Molecules

Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments. Purpose: Recently the MuCap experiment has measured the capture rate Λ_S from the singlet pμ atom, employing a low density active target to suppress ppμ formation (PRL 110, 12504 (2013)). Nevertheless, given the unprecedented precision of this experiment, the existing experimental knowledge in λ_ppμ had to be improved. Method: The MuCap experiment derived the weak capture rate from the muon disappearance rate in ultra-pure hydrogen. By doping the hydrogen with 20 ppm of argon, a competing process to ppμ formation was introduced, which allowed the extraction of λ_ppμ from the observed time distribution of decay electrons. Results: The ppμ formation rate was measured as λ_ppμ= (2.01 +- 0.06(stat) +- 0.03(sys)) 10^6 s^-1. This result updates the λ_ppμ value used in the above mentioned MuCap publication. Conclusions: The 2.5x higher precision compared to earlier experiments and the fact that the measurement was performed at nearly identical conditions to the main data taking, reduces the uncertainty induced by λ_ppμ to a minor contribution to the overall uncertainty of Λ_S and g_P, as determined in MuCap. Our final value for λ_ppμ shifts Λ_S and g_P by less than one tenth of their respective uncertainties compared to our results published earlier.

preprint2014arXiv

A high-pressure hydrogen time projection chamber for the MuCap experiment

The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, $μ^- + p \rightarrow n + ν_μ$. The experimental approach was based on the use of a time projection chamber (TPC) that operated in pure hydrogen gas at a pressure of 10 bar and functioned as an active muon stopping target. The TPC detected the tracks of individual muon arrivals in three dimensions, while the trajectories of outgoing decay (Michel) electrons were measured by two surrounding wire chambers and a plastic scintillation hodoscope. The muon and electron detectors together enabled a precise measurement of the $μp$ atom's lifetime, from which the nuclear muon capture rate was deduced. The TPC was also used to monitor the purity of the hydrogen gas by detecting the nuclear recoils that follow muon capture by elemental impurities. This paper describes the TPC design and performance in detail.

preprint2013arXiv

Measurement of Muon Capture on the Proton to 1% Precision and Determination of the Pseudoscalar Coupling g_P

The MuCap experiment at the Paul Scherrer Institute has measured the rate L_S of muon capture from the singlet state of the muonic hydrogen atom to a precision of 1%. A muon beam was stopped in a time projection chamber filled with 10-bar, ultra-pure hydrogen gas. Cylindrical wire chambers and a segmented scintillator barrel detected electrons from muon decay. L_S is determined from the difference between the mu- disappearance rate in hydrogen and the free muon decay rate. The result is based on the analysis of 1.2 10^10 mu- decays, from which we extract the capture rate L_S = (714.9 +- 5.4(stat) +- 5.1(syst)) s^-1 and derive the proton's pseudoscalar coupling g_P(q^2_0 = -0.88 m^2_mu) = 8.06 +- 0.55.

preprint2013arXiv

MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors

The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.

preprint2010arXiv

Muon Capture on the Deuteron -- The MuSun Experiment

We propose to measure the rate \Rd\ for muon capture on the deuteron to better than 1.5% precision. This process is the simplest weak interaction process on a nucleus that can both be calculated and measured to a high degree of precision. The measurement will provide a benchmark result, far more precise than any current experimental information on weak interaction processes in the two-nucleon system. Moreover, it can impact our understanding of fundamental reactions of astrophysical interest, like solar pp fusion and the $ν+d$ reactions observed by the Sudbury Neutrino Observatory. Recent effective field theory calculations have demonstrated, that all these reactions are related by one axial two-body current term, parameterized by a single low-energy constant. Muon capture on the deuteron is a clean and accurate way to determine this constant. Once it is known, the above mentioned astrophysical, as well as other important two-nucleon reactions, will be determined in a model independent way at the same precision as the measured muon capture reaction.

preprint1996arXiv

Characterization of Solidified Gas Thin Film Targets via Alpha Particle Energy Loss

A method is reported for measuring the thickness and uniformity of thin films of solidified gas targets. The energy of alpha particles traversing the film is measured and the energy loss is converted to thickness using the stopping power. The uniformity is determined by measuring the thickness at different positions with an array of sources. Monte Carlo simulations have been performed to study the film deposition mechanism. Thickness calibrations for a TRIUMF solid hydrogen target system are presented.