Source author record

C. P. Welsch

C. P. Welsch appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

12works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2021arXiv

Analysis of Proton Bunch Parameters in the AWAKE Experiment

A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. The analysis is tested on simulated data and then applied to the experimental data.

preprint2020arXiv

Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch

Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scans.

preprint2020arXiv

Proton beam defocusing in AWAKE: comparison of simulations and measurements

In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 ÷20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached only in the case of a wide enough simulation box (at least five plasma wavelengths).

preprint2017arXiv

AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch

AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %

preprint2015arXiv

AWAKE, The Advanced Proton Driven Plasma Wakefield Acceleration Experiment at CERN

The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton beam bunches from the SPS. The first experiments will focus on the self-modulation instability of the long (rms ~12 cm) proton bunch in the plasma. These experiments are planned for the end of 2016. Later, in 2017/2018, low energy (~15 MeV) electrons will be externally injected to sample the wakefields and be accelerated beyond 1 GeV. The main goals of the experiment will be summarized. A summary of the AWAKE design and construction status will be presented.

preprint2015arXiv

Path to AWAKE: Evolution of the concept

This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experimental design, where the critical issues that arose and their solutions are described. We conclude with the design of the experiment as it is being realized at CERN and some words on the future outlook. A summary of the AWAKE design and construction status as presented in this conference is given in [1].

preprint2014arXiv

A plasma wakefield acceleration experiment using CLARA beam

We propose a Plasma Accelerator Research Station (PARS) based at proposed FEL test facility CLARA (Compact Linear Accelerator for Research and Applications) at Daresbury Laboratory. The idea is to use the relativistic electron beam from CLARA, to investigate some key issues in electron beam transport and in electron beam driven plasma wakefield acceleration, e.g. high gradient plasma wakefield excitation driven by a relativistic electron bunch, two bunch experiment for CLARA beam energy doubling, high transformer ratio, long bunch self-modulation and some other advanced beam dynamics issues. This paper presents the feasibility studies of electron beam transport to meet the requirements for beam driven wakefield acceleration and presents the plasma wakefield simulation results based on CLARA beam parameters. Other possible experiments which can be conducted at the PARS beam line are also discussed.

preprint2014arXiv

Annihilation of low energy antiprotons in silicon

The goal of the AE$\mathrm{\bar{g}}$IS experiment at the Antiproton Decelerator (AD) at CERN, is to measure directly the Earth's gravitational acceleration on antimatter. To achieve this goal, the AE$\mathrm{\bar{g}}$IS collaboration will produce a pulsed, cold (100 mK) antihydrogen beam with a velocity of a few 100 m/s and measure the magnitude of the vertical deflection of the beam from a straight path. The final position of the falling antihydrogen will be detected by a position sensitive detector. This detector will consist of an active silicon part, where the annihilations take place, followed by an emulsion part. Together, they allow to achieve 1$%$ precision on the measurement of $\bar{g}$ with about 600 reconstructed and time tagged annihilations. We present here, to the best of our knowledge, the first direct measurement of antiproton annihilation in a segmented silicon sensor, the first step towards designing a position sensitive silicon detector for the AE$\mathrm{\bar{g}}$IS experiment. We also present a first comparison with Monte Carlo simulations (GEANT4) for antiproton energies below 5 MeV

preprint2013arXiv

Design of a novel electrostatic ion storage ring at KACST

A new electrostatic storage ring for beams at energies up to 30keV.q is currently under development at the National Centre for Mathematics and Physics (NCMP), King Abdulaziz City for Science and Technology (KACST). The ring design is based on the existing electrostatic storage rings, but stretches significantly beyond them in that it shall form the core of a unique flexible experimental facility at KACST. The lattice of this ring has been designed in a way that enables the use of state-of-the-art experimental methods to study electron-ion, laser-ion, and ion-neutral beams interactions. The lattice design also allows for a future upgrade of the ring to a double storage ring structure that would enable ion-ion beam interactions to be performed. In this paper, we present the design of this ring with a focus on beam dynamics calculations for the 7o single-bend racetrack layout. The study is principally based on the SIMION8 program. We complemented this study further by using purpose-written routine and MAD-X simulation code. An in-depth investigation into beam stability under consideration of non-linear field components in the electrostatic optical elements, is presented. Finally, different working points and stability regions are discussed.

preprint2013arXiv

Prospects for measuring the gravitational free-fall of antihydrogen with emulsion detectors

The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. AEgIS will measure the free-fall of an antihydrogen beam traversing a moiré deflectometer. The goal is to determine the gravitational acceleration g for antihydrogen with an initial relative accuracy of 1% by using an emulsion detector combined with a silicon micro-strip detector to measure the time of flight. Nuclear emulsions can measure the annihilation vertex of antihydrogen atoms with a precision of about 1 - 2 microns r.m.s. We present here results for emulsion detectors operated in vacuum using low energy antiprotons from the CERN antiproton decelerator. We compare with Monte Carlo simulations, and discuss the impact on the AEgIS project.

preprint2012arXiv

Beam Halo Imaging with a Digital Optical Mask

Beam halo is an important factor in any high intensity accelerator. It can cause difficulties in the control of the beam, emittance growth, particle loss and even damage to the accelerator. It is therefore essential to understand the mechanisms of halo formation and its dynamics in order to control and minimize its effects. Experimental measurement of the halo distribution is an important tool for such studies. In this paper, we present a new adaptive masking method that we have developed to image beam halo, which uses a digital micro-mirror-array device (DMD). This method has been thoroughly investigated in the laboratory using laser and white light sources, and with real beams produced by the University of Maryland Electron Ring (UMER). A high dynamic range ~10(5) has been demonstrated with this new method and recent studies indicate that this number can be exceeded for more intense beams by at least an order of magnitude. The method is flexible, easy to setup and can be used at any accelerator or light source. We present the results of our measurements of the performance of the method and images of beam halos produced under various experimental conditions.