Source author record

C. Mancini-Terracciano

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
6topics
4close collaborators

Published work

4 publications

preprint2020arXiv

Preliminary results in using Deep Learning to emulate BLOB, a nuclear interaction model

Purpose: A reliable model to simulate nuclear interactions is fundamental for Ion-therapy. We already showed how BLOB ("Boltzmann-Langevin One Body"), a model developed to simulate heavy ion interactions up to few hundreds of MeV/u, could simulate also 12^{12}C reactions in the same energy domain. However, its computation time is too long for any medical application. For this reason we present the possibility of emulating it with a Deep Learning algorithm. Methods: The BLOB final state is a Probability Density Function (PDF) of finding a nucleon in a position of the phase space. We discretised this PDF and trained a Variational Auto-Encoder (VAE) to reproduce such a discrete PDF. As a proof of concept, we developed and trained a VAE to emulate BLOB in simulating the interactions of 12^{12}C with 12^{12}C at 62 MeV/u. To have more control on the generation, we forced the VAE latent space to be organised with respect to the impact parameter (bb) training a classifier of bb jointly with the VAE. Results: The distributions obtained from the VAE are similar to the input ones and the computation time needed to use the VAE as a generator is negligible. Conclusions: We show that it is possible to use a Deep Learning approach to emulate a model developed to simulate nuclear reactions in the energy range of interest for Ion-therapy. We foresee the implementation of the generation part in C++ and to interface it with the most used Monte Carlo toolkit: Geant4.

preprint2016arXiv

Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle

Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. The secondary yields of protons produced along the primary beam path in PMMA target were obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The measured charged secondary yields and emission profiles are in agreement with the results reported in literature and confirm the feasibility of ion beam therapy range monitoring using 12C ion beam. The feasibility of range monitoring using charged secondary particles is also suggested for 4He ion beam.

preprint2013arXiv

Search for νμ→νeν_μ\rightarrow ν_e oscillations with the OPERA experiment in the CNGS beam

A first result of the search for \numu →\rightarrow \nue oscillations in the OPERA experiment, located at the Gran Sasso Underground Laboratory, is presented. The experiment looked for the appearance of \nue in the CNGS neutrino beam using the data collected in 2008 and 2009. Data are compatible with the non-oscillation hypothesis in the three-flavour mixing model. A further analysis of the same data constrains the non-standard oscillation parameters θnewθ_{new} and Δmnew2Δm^2_{new} suggested by the LSND and MiniBooNE experiments. For large Δmnew2Δm^{2}_{new} values (>>0.1 eV2^{2}), the OPERA 90% C.L. upper limit on sin2(2θnew)^{2}(2θ_{new}) based on a Bayesian statistical method reaches the value 7.2×10−37.2 \times 10^{-3}.

preprint2012arXiv

Noise correlation and decorrelation in arrays of bolometric detectors

Bolometers are phonon mediated detectors used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. They feature an excellent energy resolution, which is a few keV over an energy range extending from a few keV up to several MeV. Nevertheless the resolution can be limited by the noise induced by vibrations of the mechanical apparatus. In arrays of bolometers part of this noise is correlated among different detectors and can be removed using a multichannel decorrelation algorithm. In this paper we present a decorrelation method and its application to data from the CUORICINO experiment, an array of 62 TeO2 bolometers.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.