Researcher profile

C. Lambropoulos

C. Lambropoulos contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2011arXiv

Extensive simulation studies on the reconstructed image resolution of a position sensitive detector based on pixelated CdTe crystals

We present results on the reconstructed image resolution of a position sensitive radiation instrument (COCAE) based on extensive simulation studies. The reconstructed image resolution has been investigated in a wide range of incident photon energies emitted by point-like sources located at different source-to-detector distances on and off the detector's symmetry axis. The ability of the detector to distinguish multiple radioactive sources observed simultaneously is investigating by simulating point-like sources of different energies located on and off the detector's symmetry axis and at different positions

preprint2011arXiv

Simulated performance of a position sensitive radiation detecting system (COCAE)

Extensive simulations of a portable radiation detecting system have been performed in order to explore important performance parameters. The instrument consists of a stack of ten detecting layers made of pixelated Cadmium Telluride (CdTe) crystals. Its aim is to localize and identify radiation sources, by exploiting the Compton imaging technique. In this paper we present performance parameters based on simulation studies. Specifically the ratio of incompletely absorbed photons, the detector's absolute efficiency as well as its energy and angular resolution are evaluated in a wide range of incident photon energies.

preprint2011arXiv

Simulated Performance Of Algorithms For The Localization Of Radioactive Sources From A Position Sensitive Radiation Detecting System (COCAE)

Simulation studies are presented regarding the performance of algorithms that localize point-like radioactive sources detected by a position sensitive portable radiation instrument (COCAE). The source direction is estimated by using the List Mode Maximum Likelihood Expectation Maximization (LM-ML-EM) imaging algorithm. Furthermore, the source-to-detector distance is evaluated by three different algorithms based on the photo-peak count information of each detecting layer, on the quality of the reconstructed source image as well as on the triangulation method. These algorithms have been tested on a large number of simulated photons in a wide energy range (from 200keV up to 2MeV) emitted by point-like radioactive sources located at different orientation and source-to-detector distances.

preprint2010arXiv

Evaluation of Compton scattering sequence reconstruction algorithms for a portable position sensitive radioactivity detector based on pixelated Cd(Zn)Te crystals

We present extensive simulation studies on the performance of algorithms for the Compton sequence reconstruction used for the development of a portable spectroscopic instrument (COCAE), with the capability to localize and identify radioactive sources, by exploiting the Compton scattering imaging. Various Compton Sequence reconstruction algorithms have been compared using a large number of simulated events. These algorithms are based on Compton kinematics, as well as on statistical test criteria that exploit the redundant information of events having two or more photon interactions in the active detector's volume. The efficiency of the best performing technique is estimated for a wide range of incident gamma-ray photons emitted from point-like gamma sources.

preprint2010arXiv

Gamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector

Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of photons. A data analysis framework has been developed in order to improve the resolution of the acquired energy spectra, using specific calibration parameters for each PID350's pixel. Three PID350 detectors have been used to construct a stacked prototype system and spectroscopic measurements have been performed in order to test the ability of the prototype to localize radioactive sources.

preprint2010arXiv

Simulation studies and spectroscopic measurements of a position sensitive detector based on pixelated CdTe crystals

Simulation studies and spectroscopic measurements are presented regarding the development of a pixel multilayer CdTe detector under development in the context of the COCAE project. The instrument will be used for the localization and identification of radioactive sources and radioactively contaminated spots. For the localization task the Compton effect is exploited. The detector response under different radiation fields as well as the overall efficiency of the detector has been evaluated. Spectroscopic measurements have been performed to evaluate the energy resolution of the detector. The efficiency of the event reconstruction has been studied in a wide range of initial photon energies by exploiting the detector's angular resolution measure distribution. Furthermore, the ability of the COCAE detector to localize radioactive sources has been investigated.