Source author record

C. Alduino

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

9works
3topics
4close collaborators

Published work

9 publications

preprint2022arXiv

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ0νββ) in 130Te^{130}\text{Te}. CUORE uses a cryogenic array of 988 TeO2_2 calorimeters operated at ∼\sim10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

preprint2022arXiv

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta (0νββ0 νββ) decay. Here we show results from the search for 0νββ0 νββ decay of 130^{130}Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for 0νββ0 νββ decay and set a lower bound of T1/20ν>2.2×1025T_{1/2}^{0 ν} > 2.2 \times 10^{25} years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

preprint2022arXiv

Search for Neutrinoless β+ECβ^+EC Decay of 120^{120}Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay (0νββ0νββ) in 130^{130}Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130^{130}Te. In this work we describe a search for neutrinoless positron emitting electron capture (0νβ+EC0νβ^+EC) decay in 120^{120}Te with a total TeO2_2 exposure of 355.7 kg ⋅\cdot yr, corresponding to 0.2405 kg ⋅\cdot yr of 120^{120}Te. Albeit 0νββ0 νββ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV γγs make 0νβ+EC0νβ^+EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4⋅10223.4 \cdot 10^{22} yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of 0νβ+EC0νβ^+EC signal and set a 90% C.I. Bayesian lower limit of 2.9⋅10222.9 \cdot 10^{22} yr on 120^{120}Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

preprint2021arXiv

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta (0νββ0νββ) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO2_2 crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for 0νββ0νββ with a TeO2_2 exposure of 372.5 kg⋅\cdotyr and a median exclusion sensitivity to a 130^{130}Te 0νββ0νββ decay half-life of 1.7⋅10251.7\cdot 10^{25} yr. We find no evidence for 0νββ0νββ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of 3.2⋅10253.2\cdot 10^{25} yr on the 130^{130}Te 0νββ0νββ decay half-life. In this work, we present the current status of CUORE's search for 0νββ0νββ, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the 130^{130}Te two neutrino double-beta (2νββ2νββ) decay half-life.

preprint2019arXiv

Improved Limit on Neutrinoless Double-Beta Decay in 130^{130}Te with CUORE

We report new results from the search for neutrinoless double-beta decay in 130^{130}Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of (1.38±0.07)⋅10−2(1.38\pm0.07)\cdot10^{-2} counts/(/(keV⋅\cdotkg⋅\cdotyr)) in the 0νββ0νββ decay region of interest and, with a total exposure of 372.5 kg⋅\cdotyr, we attain a median exclusion sensitivity of 1.7⋅10251.7\cdot10^{25} yr. We find no evidence for 0νββ0νββ decay and set a 90%90\% CI Bayesian lower limit of 3.2⋅10253.2\cdot10^{25} yr on the 130^{130}Te half-life for this process. In the hypothesis that 0νββ0νββ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

preprint2018arXiv

Double-beta decay of 130{}^{130}Te to the first 0+0^+ excited state of 130{}^{130}Xe with CUORE-0

We report on a search for double beta decay of 130^{130}Te to the first 0+0^{+} excited state of 130^{130}Xe using a 9.8 kg⋅\cdotyr exposure of 130^{130}Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: τ0+0ν>7.9⋅1023τ^{0ν}_{0^+}>7.9\cdot 10^{23} yr and τ0+2ν>2.4⋅1023τ^{2ν}_{0^+}>2.4\cdot 10^{23} yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: τ0+0ν>1.4⋅1024τ^{0ν}_{0^+}>1.4\cdot 10^{24} yr and τ0+2ν>2.5⋅1023τ^{2ν}_{0^+}>2.5\cdot 10^{23} yr.

preprint2016arXiv

Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in 130^{130}Te with CUORE-0

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta (0νββ0νββ) decay in 130^{130}Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive 0νββ0νββ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final 0νββ0νββ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized 0νββ0νββ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the 0νββ0νββ decay half-life limits previously reported for CUORE-0, T1/20ν>2.7×1024T^{0ν}_{1/2}>2.7\times10^{24} yr, and in combination with the Cuoricino limit, T1/20ν>4.0×1024T^{0ν}_{1/2}>4.0\times10^{24} yr.

preprint2016arXiv

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of 130^{130}Te with an array of 988 TeO2_2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

preprint2016arXiv

The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors

The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest bolometric mass ever operated. The experiment will work at a temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free system based on pulse tubes and a custom high power dilution refrigerator, designed to match these specifications. The cryostat has been commissioned in 2014 at the Gran Sasso National Laboratories and reached a record temperature of 6 mK on a cubic meter scale. In this paper, we present results of CUORE commissioning runs. Details on the thermal characteristics and cryogenic performances of the system will be also given.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.