Source author record

Byoung-moo Ann

Byoung-moo Ann appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Motional resonances of three-dimensional dual-species Coulomb crystals

We investigate the motional resonances of dual-species Coulomb crystals comprised of $^9$Be$^+$ and $^{24}$Mg$^+$ ions held in a 4-rod linear Paul trap. Our experimental data and simulations show that the secular motion of such mixed crystals has rich dynamics. Their secular spectra can differ significantly from those of pure ion crystals. We propose a simple model based on mechanical coupling with Coulomb interactions between the two different ion species that explains many features of the secular spectrum. Our findings contribute to a more reliable identification of the ion species in mixed crystals.

preprint2016arXiv

Indirect measurement of three-photon correlation in nonclassical light sources

We have observed the three-photon correlation in nonclassical light sources by using an indirect measurement scheme based on the dead time effect of photon-counting detectors. We first developed a general theory which enables us to extract the three-photon correlation from the two-photon correlation of an arbitrary light source measured with detectors with finite dead times. We then confirmed the validity of our measurement scheme in experiments done with the cavity-QED microlaser operating with a large intra-cavity mean photon number exhibiting both sub- and super-poissoniaq photon statistics. The experimental results were in a good agreement with the theoretical expectation. Our measurement scheme provides an alternative approach for N-photon correlation measurement employing (N-1) detectors and thus a reduced measurement time for a given signal-to-noise ratio, compared to the usual scheme requiring N detectors.

preprint2015arXiv

Correction to the detector-dead-time effect on the second-order correlation of stationary sub-Poissonian light in a two-detector configuration

Exact measurement of the second-order correlation function $g^{(2)}(t)$ of a light source is essential when investigating the photon statistics and the light generation process of the source. For a stationary single-mode light source, Mandel Q factor is directly related to $g^{(2)}(t)$. For a large mean photon number in the mode, the deviation of $g^{(2)}(t)$ from unity is so small that even a tiny error in measuring $g^{(2)}(t)$ would result in an inaccurate Mandel Q. In this work, we have found that detector dead time can induce a serious error in $g^{(2)}(t)$ and thus in Mandel Q in those cases even in a two-detector configuration. Our finding contradicts the conventional understanding that detector dead time would not affect $g^{(2)}(t)$ in two-detector configurations. Utilizing the cavity-QED microlaser, a well-established sub-Poissonian light source, we measured $g^{(2)}(t)$ with two different types of photodetectors with different dead time. We also introduced prolonged dead time by intentionally deleting the photodetection events following a preceding one within a specified time interval. We found that the observed Q of the cavity-QED microlaser was underestimated by 19% with respect to the dead-time-free Q when its mean photon number was about 600. We derived an analytic formula which well explains the behavior of the $g^{(2)}(t)$ as a function of the dead time.