Source author record

Bruno Gilles

Bruno Gilles appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

Efficient Convolutional Forward Model for Passive Acoustic Mapping and Temporal Monitoring

Passive acoustic mapping (PAM) is a key imaging technique for characterizing cavitation activity in therapeutic ultrasound applications. Recent model-based beamforming algorithms offer high reconstruction quality and strong physical interpretability. However, their computational burden and limited temporal resolution restrict their use in applications with time-evolving cavitation. To address these challenges, we introduce a PAM beamforming framework based on a novel convolutional formulation in the time domain, which enables efficient computation. In this framework, PAM is formulated as an inverse problem in which the forward operator maps spatiotemporal cavitation activity to recorded radio-frequency signals accounting for time-of-flight delays defined by the acquisition geometry. We then formulate a regularized inversion algorithm that incorporates prior knowledge on cavitation activity. Experimental results demonstrate that our framework outperforms classical beamforming methods, providing higher temporal resolution than frequency-domain techniques while substantially reducing computational burden compared with iterative time-domain formulations.

preprint2020arXiv

Depressions by stacking faults in nanorippled graphene on metals

A broad variety of defects has been observed in two-dimensional materials. Many of these defects can be created by top-down methods such as electron irradiation or chemical etching, while a few of them are created along bottom-up processes, in particular during the growth of the material, in which case avoiding their formation can be challenging. This occurs e.g. with dislocations, Stone-Wales defects, or atomic vacancies in graphene. Here we address a defect that has been observed repeatedly since 2007 in epitaxial graphene on metal surfaces like Ru(0001) and Re(0001), but whose nature has remained elusive thus far. This defect has the appearance of a vacant hill in the periodically nanorippled topography of graphene, which comes together with a moir{é} pattern. Based on atomistic simulations and scanning tunneling microscopy/spectroscopy measurements, we argue that such defects are topological in nature and that their core is a stacking fault patch, either in graphene, surrounded by loops of non-hexagonal carbon rings, or in the underlying metal. We discuss the possible origin of these defects in relation with recent reports of metastable polycyclic carbon molecules forming upon graphene growth. Like other defects, the vacant hills may be considered as deleterious in the perspective of producing high quality graphene. However, provided they can be organized in graphene, they might allow novel optical, spin, or electronic properties to be engineered.

preprint2014arXiv

Lorentz-Force Hydrophone Characterization

A Lorentz-force hydrophone consists of a thin wire placed inside a magnetic field. When under the influence of an ultrasound pulse, the wire vibrates and an electrical signal is induced by the Lorentz force that is proportional to the pulse amplitude. In this study a compact prototype of such a hydrophone is introduced and characterized, and the hydrodynamic model previously developed is refined. It is shown that the wire tension has a negligible effect on the measurement of pressure. The frequency response of the hydrophone reaches 1 MHz for wires with a diameter ranging between 70 and 400 \micro m. The hydrophone exhibits a directional response such that the signal amplitude differs by less than 3dB as the angle of the incident ultrasound pulse varies from -20$^o$ and +20$^o$. The linearity of the measured signal is confirmed across the 50 kPa to 10 MPa pressure range, and an excellent resistance to cavitation is observed. This hydrophone is of interest for high pressure ultrasound measurements including High Intensity Focused Ultrasound (HIFU) and ultrasonic measurements in difficult environments.

preprint2012arXiv

Electromagnetic Hydrophone with Tomographic System for Absolute Velocity Field Mapping

The velocity and pressure of an ultrasonic wave can be measured by an electromagnetic hydrophone made of a thin wire and a magnet. The ultrasonic wave vibrates the wire inside a magnetic field, inducing an electrical current. Previous articles reported poor spatial resolution of comparable hydrophones along the axis of the wire. In this study, submillimetric spatial resolution has been achieved by using a tomographic method. Moreover, a physical model is presented for obtaining absolute measurements. A pressure differential of 8% has been found between piezoelectric and electromagnetic hydrophone measurements. These characteristics show this technique as an alternative to standard hydrophones.

preprint2009arXiv

Spin-Valve Effect of the Spin Accumulation Resistance in a Double Ferromagnet - Superconductor Junction

We have measured the transport properties of Ferromagnet - Superconductor nanostructures, where two superconducting aluminum (Al) electrodes are connected through two ferromagnetic iron (Fe) ellipsoids in parallel. We find that, below the superconducting critical temperature of Al, the resistance depends on the relative alignment of the ferromagnets' magnetization. This spin-valve effect is analyzed in terms of spin accumulation in the superconducting electrode submitted to inverse proximity effect.