Source author record

Bruce Schumm

Bruce Schumm appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

A Study of the Impact of High Cross Section ILC Processes on the SiD Detector Design

The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs created by the interaction of the colliding beams' electromagnetic fields. In order to provide hermeticity and sensitivity to beam targeting parameters, a forward Beamline Calorimeter (BeamCal) is being designed that will provide coverage down to 5 mrad from the outgoing beam trajectory, and intercept the majority of this pair background. Using the SiD simulation framework, the effect of this pair background on the SiD detector components, especially the vertex detector (VXD) and forward electromagnetic calorimeter (FCAL), is explored. In the case of the FCAL, backgrounds from Bhabha and two-photon processes are also considered. The consequence of several variants of the BeamCal geometry and ILC interaction region configuration are considered for both the vertex detector and BeamCal performance.

preprint2010arXiv

Forward Instrumentation for ILC Detectors

Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.