Source author record

Brian D. Ramsey

Brian D. Ramsey appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2023arXiv

Determination of X-ray pulsar geometry with IXPE polarimetry

Using observations of X-ray pulsar Her X-1 by the Imaging X-ray Polarimetry Explorer, we report on a highly significant ($>17σ$) detection of the polarization signal from an accreting neutron star. The observed degree of the linear polarization of $\sim$10\% is found to be far below theoretical expectations for this object, and stays low throughout the spin cycle of the pulsar. Both the polarization degree and the angle exhibit variability with pulse phase, which allowed us to measure the pulsar spin position angle 57(2) deg and the magnetic obliquity 12(4) deg, which is an essential step towards detailed modelling of the intrinsic emission of X-ray pulsars. Combining our results with the optical polarimetric data, we find that the spin axis of the neutron star and the angular momentum of the binary orbit are misaligned by at least $\sim$20 deg, which is a strong argument in support of the models explaining stability of the observed super-orbital variability with the precession of the neutron star.

preprint2022arXiv

A weighted analysis to improve the X-ray polarization sensitivity of IXPE

IXPE is a Small Explorer mission that was launched at the end of 2021 to measure the polarization of X-ray emission from tens of astronomical sources. Its focal plane detectors are based on the Gas Pixel Detector, which measures the polarization by imaging photoelectron tracks in a gas mixture and reconstructing their initial directions. The quality of the single track, and then the capability of correctly determining the original direction of the photoelectron, depends on many factors, e.g., whether the photoelectron is emitted at low or high inclination with respect to the collection plane or the occurrence of a large Coulomb scattering close to the generation point. The reconstruction algorithm used by IXPE to obtain the photoelectron emission direction, also calculates several properties of the shape of the tracks which characterize the process. In this paper we compare several such properties and identify the best one to weight each track on the basis of the reconstruction accuracy. We demonstrate that significant improvement in sensitivity can be achieved with this approach and for this reason it will be the baseline for IXPE data analysis.

preprint2022arXiv

Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation

IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

preprint2022arXiv

Limits on X-ray Polarization at the Core of Centaurus A as Observed with the Imaging X-ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the $2-8 \thinspace \mathrm{keV}$ band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at $99 \%$ percent confidence (MDP$_{99}$) of $6.5 \%$ using a weighted, spectral model-independent calculation in the $2-8 \thinspace \mathrm{keV}$ band. The polarization angle $ψ$ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy ($0.3-400 \thinspace \mathrm{keV}$) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption ($N_H \sim 10^{23} \thinspace \mathrm{cm}^{-2}$) and a Fe K$α$ emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below $2 \thinspace \mathrm{keV}$. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe K$α$ emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

preprint2022arXiv

Simultaneous space and phase resolved X-ray polarimetry of the Crab Pulsar and Nebula

The Crab pulsar and its nebula are among the most studied astrophysical systems, and constitute one of the most promising environments where high energy processes and particle acceleration can be investigated. They are the only objects for which previous X-ray polarisation has been reported. We present here the first Imaging X-ray Polarimetry Explorer (IXPE) observation of the Crab pulsar and nebula. The total pulsar pulsed emission in the [2-8] keV energy range is unpolarised. Significant polarisation up to 15% is detected only in the core of the main peak. The nebula has a total space integrated polarised degree of 20% and polarisation angle of 145deg. The polarised maps show a large variation in the local polarisation, and regions with polarised degree up to 45-50%. The polarisation pattern suggests a predominantly toroidal magnetic field.

preprint2021arXiv

An algorithm to calibrate and correct the response to unpolarized radiation of the X-ray polarimeter on board IXPE

The Gas Pixel Detector is an X-ray polarimeter to fly on-board IXPE and other missions. To correctly measure the source polarization, the response of IXPE's GPDs to unpolarized radiation has to be calibrated and corrected. In this paper we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and non-monochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

preprint2013arXiv

Demonstration of a novel focusing small-angle neutron scattering instrument equipped with axisymmetric mirrors

Small-angle neutron scattering (SANS) is the most significant neutron technique in terms of impact on science and engineering. However, the basic concept of SANS facilities has not changed since the technique's inception about 40 years ago, as all SANS instruments, save a few, are still designed as pinhole cameras. Here we demonstrate a novel concept for a SANS instrument, based on axisymmetric focusing mirrors. We build and test a small prototype, which shows a performance comparable to that of conventional large SANS facilities. By using a detector with 50-micron pixels, we build the most compact SANS instrument in the world. This work, together with the recent demonstration that such mirrors could increase the signal rate at least 50-fold, while improving resolution, paves the way to novel SANS instruments, thus affecting a broad community of scientists and engineers.

preprint2012arXiv

Axisymmetric Grazing-Incidence Focusing Optics for Small-Angle Neutron Scattering

We propose and design novel axisymmetric focusing mirrors, known as Wolter optics, for small-angle neutron scattering instruments. Ray-tracing simulations show that using the mirrors can result in more than an order-of-magnitude increase in the neutron flux reaching detectors, while decreasing the minimum wave vector transfer. Such mirrors are made of Ni using a mature technology. They can be coated with neutron supermirror multilayers, and multiple mirrors can be nested to improve their flux-collection ability. Thus, these mirrors offer simple and flexible means of significantly improving existing and future SANS instruments. In addition, short SANS instruments might become possible, especially at compact neutron sources, when high-resolution detectors are combined with Wolter optics.

preprint2010arXiv

Methods of optimizing X-ray optical prescriptions for wide-field applications

We are working on the development of a method for optimizing wide-field X-ray telescope mirror prescriptions, including polynomial coefficients, mirror shell relative displacements, and (assuming 4 focal plane detectors) detector placement along the optical axis and detector tilt. With our methods, we hope to reduce number of Monte-Carlo ray traces required to search the multi-dimensional design parameter space, and to lessen the complexity of finding the optimum design parameters in that space. Regarding higher order polynomial terms as small perturbations of an underlying Wolter I optic design, we begin by using the results of Monte-Carlo ray traces to devise trial analytic functions, for an individual Wolter I mirror shell, that can be used to represent the spatial resolution on an arbitrary focal surface. We then introduce a notation and tools for Monte-Carlo ray tracing of a polynomial mirror shell prescription which permits the polynomial coefficients to remain symbolic. In principle, given a set of parameters defining the underlying Wolter I optics, a single set of Monte-Carlo ray traces are then sufficient to determine the polymonial coefficients through the solution of a large set of linear equations in the symbolic coefficients. We describe the present status of this development effort.

preprint2010arXiv

ProtoEXIST: Advanced Prototype CZT Coded Aperture Telescopes for EXIST

{\it ProtoEXIST1} is a pathfinder for the {\it EXIST-HET}, a coded aperture hard X-ray telescope with a 4.5 m$^2$ CZT detector plane a 90$\times$70 degree field of view to be flown as the primary instrument on the {\it EXIST} mission and is intended to monitor the full sky every 3 h in an effort to locate GRBs and other high energy transients. {\it ProtoEXIST1} consists of a 256 cm$^2$ tiled CZT detector plane containing 4096 pixels composed of an 8$\times$8 array of individual 1.95 cm $\times$ 1.95 cm $\times$ 0.5 cm CZT detector modules each with a 8 $\times$ 8 pixilated anode configured as a coded aperture telescope with a fully coded $10^\circ\times10^\circ$ field of view employing passive side shielding and an active CsI anti-coincidence rear shield, recently completed its maiden flight out of Ft. Sumner, NM on the 9th of October 2009. During the duration of its 6 hour flight on-board calibration of the detector plane was carried out utilizing a single tagged 198.8 nCi Am-241 source along with the simultaneous measurement of the background spectrum and an observation of Cygnus X-1. Here we recount the events of the flight and report on the detector performance in a near space environment. We also briefly discuss {\it ProtoEXIST2}: the next stage of detector development which employs the {\it NuSTAR} ASIC enabling finer (32$\times$32) anode pixilation. When completed {\it ProtoEXIST2} will consist of a 256 cm$^2$ tiled array and be flown simultaneously with the ProtoEXIST1 telescope.